background image

ORIGINAL INSTRUCTIONS > EN

1. SAFETY INSTRUCTIONS

The operator must know the principles of functioning and the structure of the generator and the

motor. He must know how to stop the motor in case of urgency and how to manipulate the

controls.

Never let children use this device.

Never let people who do not know these instructions use this device. Local regulations may

impose restrictions on the age of the user.

Please do not use this device when people, especially children, or pets are nearby. Direct them

away from the working area.

The operator or the user are responsible for possible accidents or damage to other persons or

to their property.

Do not wear loose clothing or jewellery as this can get caught in the machinery as it runs.

Use safety equipment. Wear protective gear such as an anti-dust mask, non-slip safety shoes,

helmet or hearing protection.

Stay vigilant, watch what you are doing and show good sense when you use the generator. Do

not use if you are tired or under the influence of drugs, alcohol or medicines.

Install the generator in a place that is well ventilated and make sure that there is at least 1.5

meters between the generator and the walls of the building or other equipment. Do not place

flammable liquids or gases near the generator.

Do not run the generator in an enclosed or badly-ventilated space. The exhaust gas from the

motor contains carbon monoxide which is toxic and may lead to a loss of consciousness or

death.

Run the generator in respect of the power indicated in the user’s manual. Do not run the

generator with an overload or at excessive speed.

The silencer of the generator becomes extremely hot when the motor runs or even for a time

after it has stopped. Do not touch it as it will burn you.

Do not transport or move the generator until it has cooled down.

Perform periodic maintenance and resolve problems that appear immediately. Do not run the

generator before correcting any fault detected.

The generator uses a system of air-cooling, and it is necessary to clean its components

regularly, including the grilles, the cover of the fan and the fan itself so as to ensure cooling.

Keep the fuel filter clean, and change the oil of the motor regularly.

Periodically check the installation of the connections and the tightness of the fixations, re-

tightening them if necessary.

Clean the components of the air filter periodically, and replace the air filter when necessary.

Remove any electrical equipment that is plugged in before starting or stopping the generator.

Before transporting the generator, you must empty the fuel tank.

Maintenance and repair of the generator must be carried out by a qualified technician from an

authorized after-sales service center.

The adjustment points of the machine shall not be modified by the end-user. Any modification

shall be done by a qualified service.

Attention! Exhaust gases, oil and fuel are toxic. Do not operate the generator in a room without

ventilation system.

Refilling of the generating sets is not allowed during the operation.

If the generator will be mounted in a closed room, relevant safety regulations against fire and

explosion should be followed.

Do not connect to household circuit.

03

Содержание FGH3500

Страница 1: ...NAL INSTRUCTIONS EN LOW POWER DUAL FUEL GENERATOR MODEL FGH3500 BUILDER SAS ZI 32 rue Aristide Berg s 31270 Cugnaux France Made in P R C 2022 Warning Please read the manual carefully before using the...

Страница 2: ...TY INSTRUCTIONS 3 2 COMPONENT IDENTIFICATION 7 3 ASSEMBLY 8 4 OPERATION 13 5 MAINTENANCE AND STORAGE 17 6 SPECIFICATIONS 21 7 TROUBLESHOOTING 22 8 DECLARATION OF CONFORMITY 23 9 WARRANTY 24 10 PRODUCT...

Страница 3: ...er indicated in the user s manual Do not run the generator with an overload or at excessive speed The silencer of the generator becomes extremely hot when the motor runs or even for a time after it ha...

Страница 4: ...in ventilated rooms additional requirements for fire and explosion protection shall be observed Before use the generating set and its electrical equipment including lines and plug connections should...

Страница 5: ...sions make sure that they are sufficiently thick to transport the current and that they are used correctly The connection of a generator used for auxiliary power to the electrical installation of a bu...

Страница 6: ...ty as gas needs room to expand if temperatures rise Liquefied Petroleum Gas LPG with Propane LPG with Propane IS HIGHLY FLAMMABLE AND EXPLOSIVE Flammable gas under pressure can cause a fire or explosi...

Страница 7: ...haust emissions are harmful to health of body No naked fire near the machine Do not connect with the electricity system Danger Electrical shock 2 COMPONENT IDENTIFICATION l Gas Fuel Tank 15L capacity...

Страница 8: ...op to bottom Fold each side flat on the ground to provide a surface area to install the wheel kit and support leg Install the Wheel Kit CAUTION The wheel kit is not intended for over the road use You...

Страница 9: ...ttery 2 Attach the red lead to the red terminal on the battery with the cap screw M5x10 and secure with the nut M5 3 Repeat steps 1 2 for the black battery lead Add Engine Oil CAUTION DO NOT attempt t...

Страница 10: ...e If using the dipstick to check oil level DO NOT screw in the dipstick while checking CAUTION The engine is equipped with a low oil shut off and will stop when the oil level in the crankcase falls be...

Страница 11: ...ular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately 1 4 in 6 4 mm below the top of the tank to allow for fuel expansion DO NOT pump gas dir...

Страница 12: ...plugged or kept closed must also be purged The purging process should be done by a LPG with Propane supplier Cylinders from an exchange supplier should have been purged and filled properly already Alw...

Страница 13: ...where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents when positioning generator Failure to follow proper safety precautions may void manufacture...

Страница 14: ...n a flat level surface 2 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 3 Turn the gasoline fuel valve to the ON p...

Страница 15: ...Press and hold the ignition switch to the START position Release as the engine begins to start If the engine tails to start within five seconds release the switch and wait at least ten seconds before...

Страница 16: ...these simple steps to calculate the running and starting watts necessary for your purposes 1 Select the electrical devices you plan on running at the same time 2 Total the running watts of these item...

Страница 17: ...sition Important Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the engine is not in use NOTE When turning off the generator after LPG with Propane operation make...

Страница 18: ...nto the engine 7 Use the spark plug tool to firmly install the plug 8 Attach the spark plug wire to the plug Air Filter 1 Remove the snap on cover holding the air filter to the assembly 2 Remove the f...

Страница 19: ...service intervals indicated in the following maintenance schedule Service your generator more frequently when operating in adverse conditions CAUTION DO NOT use a garden hose to clean the generator W...

Страница 20: ...lug 11 Store the unit in a clean dry place out of direct sunlight DANGER Generator exhaust contains odorless and colorless carbon monoxide gas To avoid accidental or unintended ignition of your remote...

Страница 21: ...ooling OHV Displacement CC 224cc Rated speed 5 0kW 3600 min Igniting system TCI Starting system Electric Recoil Fuel Volume L 15 L Continuous operation time h 8 h Min Fuel consumption g kW h 360 g kW...

Страница 22: ...om doors windows and other vents 7 TROUBLESHOOTING Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during start up Remove load from un...

Страница 23: ...tive 2014 30 EU ROHS Directive EU 2015 863 amending 2011 65 EU Emission directive EU 2016 1628 2017 656 EU Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies with European standards with nat...

Страница 24: ...he user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifcations without notice Consequently the product may be diferent from the information co...

Страница 25: ...pairs will be done by approved engine manufacturers of these manufacturers see their site http www briggsandstratton com eu fr http www honda engines eu com fr service network page jsessionid 5EE8456C...

Страница 26: ...sary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair stat...

Отзывы: