ORIGINAL INSTRUCTIONS > EN
Every 250 hours
Clean combustion chamber*
Every 3 years
Replace fuel line and LPG(
with Propane
) hose
*To be performed by knowledgeable, experienced owners or Hyundai certified dealers.
Generator Maintenance
Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level
surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive
dust, dirt, moisture or corrosive vapors.
Storage
The generator should be started at least once every 14 days and allowed to run for at least 20 minutes. For
longer term storage, please follow these guidelines.
Generator Storage
1. Add a properly formulated fuel stabilizer to the tank.
2. Be sure all appliances are disconnected from the generator.
3. Run the generator for a few minutes so the treated fuel cycles through the fuel system and carburetor.
4. Turn the fuel valve to the “Off” position.
5. Let the generator run until fuel starvation has stopped the engine. This usually takes a few minutes.
6. The generator needs to cool completely before cleaning and storage.
7. Remove the spark plug cap, then pull the recoil grip 3 times to drain the gasoline from the carburetor jets.
8. Change the engine oil.
9. Remove the spark plug and pour about a tablespoon of oil into the cylinder. Crank the engine slowly to
distribute the oil and lubricate the cylinder.
10. Reattach the spark plug.
11. Store the unit in a clean, dry place out of direct sunlight.
DANGER!
Generator exhaust contains odorless and colorless carbon monoxide gas.
To avoid accidental or unintended ignition of your remote start generator during periods of storage the
following precautions should be followed:
When storing the generator for short periods of time make sure that the Ignition Switch, the Fuel valve and
the Battery Switch are set in the OFF position.
When storing the generator for extended periods of time make sure that the Ignition Switch, the
Fuel Valve and the Battery Switch are set in the OFF position and the battery leads have been
disconnected from the battery
Generator Battery
This product is equipped with an automatic battery charging circuit. The battery will receive charging
voltage when the engine is running. The battery maintain a proper charge if the unit is used on a regular
basis (about once every two weeks). If it is used less frequently, the battery should be connected to a
trickle charger or battery maintainer to keep the battery properly charged. If the battery is not able to start
the engine, it can be started by manually pulling the engine recoil cord. If the battery voltage is extremely
low, the charging circuit may not be able to re-charge the battery. In this case, the battery must be
connected to a standard automotive style battery charger for re-charging before it can be used
Disconnect the Battery
1. Remove the protective cover from the black / negative battery lead
2. Disconnect the black / negative lead from the black /negative terminal on the battery and store the cap
20