Although it is extremely versatile,
the SmartSystem-LMS (Model
SS2000C31) is operational right out
of the box. It comes preconfigured ac-
cording to the chart to the right. All
operation instructions on this page
will be in reference to the default
configuration.
Many of these functions, as well as
some not listed, can be changed to
meet the user’s specific needs. Make
sure to take the time to read through
this manual to understand the full
versatility of this product.
All warnings and cautions that ap-
pear in the SS2000C31 hardware in-
stallation and maintenance manual
also apply to information given in
this manual. Make sure you are
aware of these warnings and cau-
tions before you begin using this
manual and reconfiguring the
SS2000C31 system.
DEFAULT CONFIGURATION
Load Manager Voltage
Threshold - 11.0V, 11.8V, and 12.8V
Low Voltage Alarm - Enabled.
Load Shedding Sequence -
Relay E, D, C, B, A, 1, and 2.
MAN - Will produce peak & hold
tone when no other sirens are active.
If wail or yelp are active, the tone
will change to priority for 8-seconds
then revert back to the previous
tone. Horn Ring will do the same if
it is transferred to the siren.
A/H - Will produce Air Horn tone any
time it is pressed.
LRC O - Directional light Arrow
Step through (Left, Right, Center
Out, Off).
WARN - Directional light Warn Step
through (Warn 1, 2, 3, 4 & Off).
FAST - Directional light Arrows and
Warn - fast speed override.
LO PWR - Directional light Arrows
- Low Power Pattern override.
COMMON MIC. Control - enabled.
HI IDLE Control - disabled.
Slide Switch Position 1 - Activates
relay 1 and Warn-1 on directional
light.
Slide Switch Position 2 - Activates
relay 1 & 2, Warn 2 on directional
light, and the Horn Ring Transfer
Relay.
Slide Switch Position 3 - Activates
relay 1, 2, & 3, Warn 3 on directional
light, the Horn Ring Transfer Relay,
and enables the Siren.
Auxiliary relay keys A-E activate
the corresponding relays and are all
Push On/Push Off type functions.
STBY - Turns off sirens.
RAD- Turns on Radio Rebroadcast.
WAIL - Wail tone will activate only
when the siren is enabled. In the
default configuration, only mode 3
enables the siren.
YELP - Yelp tone will activate only
when the siren is enabled.
PRTY - Priority tone will activate
only when the siren is enabled.
OPERATION
-1-
SmartSystem-LMS
9
10
11
12
13
14
15
16
4
5
6
7
8
20
19
17
18
OFF
1
2
3
LRC O
WARN
STBY
PA/
HI IDL
RAD
WAIL
YELP
PRTY
C
B
A
D
E
MAN
A/H
FAST
LOPWR
290A4318-01