manualshive.com logo in svg
background image

Although  it  is  extremely  versatile,
the  SmartSystem-LMS  (Model
SS2000C31) is operational right out
of the box. It comes preconfigured ac-
cording to the chart to the right. All
operation instructions on this page
will  be  in  reference  to  the  default
configuration.

Many of these functions, as well as
some  not  listed,  can  be  changed  to
meet the user’s specific needs. Make
sure to take the time to read through
this manual to understand the full
versatility of this product.

All warnings and cautions that ap-
pear in the SS2000C31 hardware in-
stallation and maintenance manual
also  apply  to  information  given  in
this  manual.  Make  sure  you  are
aware  of  these  warnings  and  cau-
tions  before  you  begin  using  this
manual  and  reconfiguring  the
SS2000C31 system.

DEFAULT CONFIGURATION

Load Manager Voltage
Threshold 
- 11.0V, 11.8V, and 12.8V

Low Voltage Alarm - Enabled.

Load Shedding Sequence -
Relay E, D, C, B, A, 1, and 2.

MAN  -  Will  produce  peak  &  hold
tone when no other sirens are active.
If  wail  or  yelp  are  active,  the  tone
will change to priority for 8-seconds
then  revert  back  to  the  previous
tone. Horn Ring will do the same if
it is transferred to the siren.

A/H - Will produce Air Horn tone any
time it is pressed.

LRC    O  -  Directional  light  Arrow
Step  through  (Left,  Right,  Center
Out, Off).

WARN - Directional light Warn Step
through (Warn 1, 2, 3, 4 & Off).

FAST - Directional light Arrows and
Warn - fast speed override.

LO PWR - Directional light Arrows
- Low Power Pattern override.

COMMON MIC. Control - enabled.

HI IDLE Control - disabled.

Slide Switch Position 1 - Activates
relay  1  and  Warn-1  on  directional
light.

Slide Switch Position 2 - Activates
relay  1  &  2, Warn  2  on  directional
light,  and  the  Horn  Ring  Transfer
Relay.

Slide Switch Position 3 - Activates
relay 1, 2, & 3, Warn 3 on directional
light, the Horn Ring Transfer Relay,
and enables the Siren.

Auxiliary relay keys A-E activate
the corresponding relays and are all
Push On/Push Off type functions.

STBY - Turns off sirens.

RAD- Turns on Radio Rebroadcast.

WAIL - Wail tone will activate only
when  the  siren  is  enabled.  In  the
default  configuration,  only  mode  3
enables the siren.

YELP - Yelp tone will activate only
when the siren is enabled.

PRTY  -  Priority  tone  will  activate
only when the siren is enabled.

OPERATION

-1-

SmartSystem-LMS

9

10

11

12

13

14

15

16

4

5

6

7

8

20

19

17

18

OFF

1

2

3

LRC O

WARN

STBY

PA/

HI IDL

RAD

WAIL

YELP

PRTY

C

B

A

D

E

MAN

A/H

FAST

LOPWR

290A4318-01

Содержание SmartSystem SS2000C31

Страница 1: ...OPERATION AND CONFIGURATION INSTRUCTIONS Model SS2000C31 SmartSystem Load Management System LOAD MANAGER WITH ELECTRONIC SIREN LIGHT CONTROL SYSTEM AND DIRECTIONAL LIGHT with Slide Switch Control Head...

Страница 2: ...h examination reveals a defect in material and or workmanship This warranty does not cover travel expenses the cost of specialized equipment for gaining access to the product or labor charges for remo...

Страница 3: ...g will do the same if it is transferred to the siren A H Will produceAir Horn tone any time it is pressed LRC O Directional light Arrow Step through Left Right Center Out Off WARN Directional light Wa...

Страница 4: ...ring process You will find that filling out the worksheet will help greatly reduce the time needed to configure your system to meet your requirements Once you have determined how your system should op...

Страница 5: ...ux Relay Push on Push off Momentary 8 Second Timer Security Timer LEVEL 3 Power Up Select which keys should automatically activate when first powered up LEVEL 4 Horn Ring Select Horn Ring Transfer Fun...

Страница 6: ...4...

Страница 7: ...less effective at warning others Maximum sound output will be severely re duced if any objects are in front of the speaker If your installation has obstructions in front of the speaker drive even more...

Страница 8: ...nd the configuration session and put the system into op eration mode LEVEL 1 Pressing LEVEL 1 Key 10 will enter LEVEL 1 Keyboard If LEVEL 1 is selected go to page 7 LEVEL 1 Keyboard LEVEL 2 Pressing L...

Страница 9: ...fore the siren tone will be produced Which slide switch will turn on the sirens is optional and will be dis cussed in Level 2 Slide Switch Function on page 10 Default Configuration If key 15 is on th...

Страница 10: ...Slide Switches is selected go to page 9 Level 2 Slide Switches Aux Relay Keys Pressing Aux Relay Keys Key 14 will enter LEVEL 2 Aux Relay Keys If Aux Relay Keys is selected go to page 11 Level 2 Aux...

Страница 11: ...gure Slide Switch 1 Slide 2 Press Slide 2 to reconfigure how Slide Switch position 2 functions If Slide 2 is selected go to Level 2 Slide Switch Function page 10 to reconfigure Slide Switch 2 Slide 3...

Страница 12: ...n be con figured to automatically turn on with the Slide Switches To do so turn on Key 15 Horn Ring Trans fer Siren Enable If sirens are configured to be depen dent on the slide switch this is where y...

Страница 13: ...ux Relay C Press Aux Relay C to reconfigure how Aux Relay C key 6 functions IfAux Relay C is selected go to Level 2 Aux Relays Function page 12 to reconfigure Aux Relay C Aux Relay D Press Aux Relay D...

Страница 14: ...t the Aux Relay you are con figuring to automatically turn itself off after 8 seconds Security Timer Select Security Timer Key 15 if you want the Aux Relay you are con figuring to require security ope...

Страница 15: ...s page 8 RAD WAIL YELP MAN A H Turn on the key to enable one of the above tones key Turn off the key to disable one of the above tones key H L or PRIORITY Key 14 can be configured to activate either t...

Страница 16: ...omatically when the system is powered up Remember only one siren or the RAD key can be selected at a time If no sirens or RAD is selected the system will power up in stand by Note If the sirens are co...

Страница 17: ...and you press the horn If the tone cannot transfer to a more urgent tone the Air Horn will mo mentarily sound Activate key 13 if you want YELP to be this tone Activate key 14 if you want PRIORITY No...

Страница 18: ...quence Press key 10 Load Shed Sequence to reconfigure how the load manager man ages relays It can be configured so that relay outputs are not managed Relays then opreate in a normal on off control mod...

Страница 19: ...nds or more If the High Idle Control is enabled High Idle will activate to remedy the low battery condition before load shedding begins Previously shed loads are NOT restored if the bat tery voltage r...

Страница 20: ...d Management page 16 Lower Voltage The lower voltage threshold programming can be performed only when key 12 is pressed and the key 12 LED turns on Press key 12 to enable lower voltage threshold progr...

Страница 21: ...on EXIT C1 C2 C3 Shed load according to the programmed sequence Volts 13 8V for 30 sec Volts 12 8V for 30 sec Volts 12 8V for 30 sec Turn High Idle Off NOTE 11 8V 12 8V AND 13 8V CAN BE PROGRAMMED TO...

Страница 22: ...ren Enable Circle the tones switches to be enabled RAD WAIL YELP H L or PRIORITY MAN A H Level 1 Sirens independent of slide switch Yes No Function Indicator Sound Yes No Directional light Type 6 Lamp...

Страница 23: ...mperes max Relay 2 20 amperes max Relay 3 40 amperes max Relay A 10 amperes max Relay B 10 amperes max Relay C 10 amperes max Relay D 10 amperes max Relay E 10 amperes max Is Horn Ring Transfer used Y...

Страница 24: ...Printed in U S A 255352A REV A 903...

Отзывы: