Chapter 3: Wiring the Convergence Network
SmartSiren Platinum Convergence Network
25
Connections for Rear External Discrete SignalMaster (SSP3000B Only)
Cable assembly 1751542-01 includes 18-inch, 20 AWG wires for six-head and eight-head
SignalMaster lightbars that are wired discretely. These directional warning lights are standalone
lightbars, rather than part of a full-featured, serial-controled lightbar, with separate wires for
each lighthead. The Convergence network accepts up to four SignalMaster lightbars of any type.
The SignalMaster has these software-configurable options:
◆
Step-through selection of up to four directional warn patterns
◆
Four SAE directional warn patterns
◆
Ten non-SAE warn patterns
◆
Fast and low-power
Figure 3.8 shows the connectors for a six and an eight-head SignalMaster on the back of
the amplifier/relay module. Extend the red power wire with an 18 AWG lead or thicker. The
SignalMaster is fused on the top of the siren amplifier/relay module with a 20 A mini-blade
LED fuse.
Extend wiring to the SignalMaster lightheads with 20 AWG leads or thicker. Insulate spliced
leads with twist-on wire connectors. Fold and seal unused leads.
Figure 3.8
Connections for discretely wired SignalMaster
S
IGNAL
M
ASTER
, RELAY & INPUTS
CABLE ASSY. P/N 1751542
SM
1
SM
2
SM
3
SM
4
SM
5
SM
6
SM
7
SM
8
8-HEAD
S
IGNAL
M
ASTER
6-HEAD
S
IGNAL
M
ASTER
SM POWER OUT (20 A
FUSE ON TOP OF SIREN)
WHITE
BROWN
GREEN
ORANGE
VIOLET
YEL
LOW
GR
AY
BLUE
RED 18 AWG
SM SM SM SM SM SM
1
2
3
4
5
6
20 AWG
20 AWG
TO SM
RED
WIRE
10 8 6 4 2
9
5
7
3 1
AUX
2 3
3
4
4
5 6 7 8
1
11 1 1 1 1
2
2 3 4
AUX
PARK
INPUT
+12V
+
P
SM
290A6545