![background image](http://html1.mh-extra.com/html/federal-signal-corporation/smartsiren-platinum-ssp2000b/smartsiren-platinum-ssp2000b_installation-and-maintenance-instructions-manual_3815024023.webp)
Chapter 3: Wiring the Convergence Network
SmartSiren Platinum Convergence Network
23
Figure 3.6
Connection for 10 A solid-state auxiliary relays
10 8 6 4 2
9
5
7
3 1
AUX
2 3
3
4
4
5 6 7 8
1
11 1 1 1 1
+12v
2
2 3 4
SM
AUX
INPUT
10
A RELAY LEADS
CABLE ASSY. P/N 1751541
10 8
6
4
2
9
7
5
3
1
WHITE
BROWN
GREEN
BLUE
RED
ORANGE
YELLOW
VIOLET
GRAY
BLACK
TEN 10
A FUSES
ON TOP OF SIREN
FOR 10
A RELAYS
AUX
18 AWG
AUX
Connections for Low-Current Auxiliary Relays
Cable assemblies 1751542-NY (SSP2000B) and 1751542-01 (SSP3000B) includes
18-inch, 18 AWG leads for four solid-state relays. The relays are 12 Vdc out only (active high)
with these software-configurable options:
◆
Steady-on lighting or one of five flash rates for small flashing lights.
◆
Synchronized or alternating flashing for two or more small flashing lights.
Figure 3.7 on page 24 shows the connectors for the relay cable assembly on the back of the siren
amplifier/relay module. The relays are protected inside the module by electronic short-circuit
detection circuits.
Extend wiring with 18 AWG leads or thicker. Insulate spliced leads with twist-on wire
connectors. Fold and seal unused leads.
Table 3.2
Configurable activation options for 2 A solid-state relays
Configured
Activation
Description
Diagram
Active High
The relay su12 Vdc during the “on” state.
OUT
+12 V
Open Off
The NC relay is open during the “off” state, a con-
dition similar to an open electromechanical relay.
OUT
+12 V