Configuring the Internal Relays
79
SmartSiren Platinum Series
10 8 6
4 2
9
5
7
3 1
AUX
2 3
3
4
4
5 6 7 8
1
11 1 1 1
1
+12v
2
2 3 4
SM
AUX
INPUT
ACTIVE HIGH/LOW
RELAYS 1–10
ACTIVE HIGH
RELAYS 1–4
Pins for Internal Solid State Relay
Switch Positions for Internal Solid State Relays
Function
Description
Active High
The normally closed (NC) relay su12 Vdc during the “on” state.
Active Low
The NC relay supplies ground during the “on” state.
Open Off
The NC relay is open during the “off” state, a condition similar to an open
electromechanical relay.
Inverse Off
The NC relay alternates from its former polarity to the other each time it
is in the “off” state.
ON
OFF
ON
OFF
ACTIVE HIGH
ACTIVE LOW
INVERSE OFF
OPEN OFF
−GND
+12 V
OUT
+12 V
OUT
+12 V
OUT
+12 V
OUT
−GND
−GND
−GND
OUT
−GND
OUT
OUT
OUT
+12 V
+12 V
Содержание SmartSiren Platinum Series
Страница 1: ...Control Pad Configuration Software Manual 2562418C REV C 411 Printed in U S A...
Страница 6: ...6...