
Configuring the Internal Relays
76
SmartSiren Platinum Series
Configuring the Internal Relays for the Slide Switch Buttons
1.
Click a
Slide Switch
button.
NO
TE
Button Function Limits
The functions for all buttons (except
Slide Switch 3
, which accepts a limit of 20)
are limited to a maximum of 10.
2.
If the
Siren
pane is not in front of the other
Device Selection
panes, click the
Siren
tab.
3.
Select a relay for configuration. The relay is highlighted so that you can easily see it for editing.
The other relays dim until you complete the configuration of the relay by selecting the options on
the right. For a description of the options, see the tables on pages 79 and 80.
Содержание SmartSiren Platinum Series
Страница 1: ...Control Pad Configuration Software Manual 2562418C REV C 411 Printed in U S A...
Страница 6: ...6...