112
Control Panel Designer
PAGASYS GEN II (P-SYS-G)
Federal Signal www.fedsig.com
13.1.1 Configuring a new Access Panel Button
To configure a new Access Panel button:
1. Go to the item select list under equipment tree, select Access Panel Button, and select
Add to add the new Access Panel Button.
2. Select the new Access Panel Button and configure an available Button ID.
3. In the Name box, type a name.
4. In the Comments box, type a comment.
5. From the Settings section, click the Sense arrow: typically Normally Open/NDE.
6. From the Settings section, click the Mode arrow: typically Toggled.
7. From the Visibility section, set Visibility desired.
8. From the Input-Function section, set the Function values. Function for a typical
alarm broadcast button are input_channel_bcast_req_fixed_zones or input_channel_
bcast_req_variable_zones, which differ in how output zones are selected.
9. In the Parameters section, under the Broadcast ID tab, in the Broadcast box, select
the broadcast (use the ID for the new broadcast).
10. In the Parameters section, under the Zone List tab, in the Broadcast box, select the
zone.
13.1.2 Creating the new Access Indicator for the Access Panel Button
To create a new Access Panel Indicator for the Access Panel Button that was created
using the System Manager software:
1. Select Configuration > Equipment.
2. From the list, scroll to Soft Panel/Access Panel 33. With the access panel selected,
Add a new Access Panel Indicator.
• Go to the item select list under equipment tree, select Access Panel Indicator, and
select the Add button to add the new Access Panel Indicator
• Select the new Access Panel Indicator and configure an Indicator ID that matches
the Button ID for the new Access Panel Button. Give the indicator a Name,
Scope, and set Output-Function to indicator_simple.
3. Access the Access Panel Button associated with this indicator, and add a connection
under Connection-Output to drive the Access Panel Indicator under the State tab.
4. If a Lamp Test option is available on the system, access the Lamp Test button on the
soft access panel, and add this new Access Panel Indicator to the list of Connection-
Outputs