22
IMPAXX
®
IPX600 Series LED Light Heads
Federal Signal
www.fedsig.com
Selecting a Flash Pattern
will flash once almost immediately after you tap the green
pattern-selection wire; after this flash, remove ground
(–GND).
2.
To reverse the direction of pattern selection, hold the green
wire to ground (–GND) for slightly longer than 1 second but
less than 3 seconds. The light head will flash twice after one
second. Once the double flash is finished, remove ground
(–GND).
Now every time the green pattern-selection wire is tapped,
the patterns change in the reverse order.
3.
When you are finished, cut and seal the green wire.
Synching and Alternating Light Heads
If an IPX600 is set to be a follower and has more than one
color, you can change which color it will sync to on power up.
This provides a basic way to sync or alternate colors. When
configured as a follower, the IPX600 changes its color after an
off time of 160 milliseconds. Color syncing works best when
the light heads that are synced together are of the same LED
configuration. For wiring diagrams, see Figure 3 below and
Figure 4 on page 23.
Figure 3 Wiring for synchronized lights
Synchronized
Controller
Light Head
*Fuse Requirements:
1 To 3 Light Heads = 5 A
4 To 6 Light Heads = 10 A
Steady Burn Pulls 1 A
12 Vdc (+BAT)
Red
Red
Yellow
Yellow
White
White
Black
Black
Fuse*
(–GND)
Follower
Light Head
Steady Burn /
Flash White
(Optional)
Power