Safety Messages

•  Refer to the manual packed with the lighting system for 

proper electrical connections, additional precautions and 

information. 

•  Locate the light system controls so the VEHICLE and 

CONTROLS can be operated safely under all driving 

conditions.

After Installation or Service

•  After installation, test the light system to ensure that it is 

operating properly.

•  Test all vehicle functions, including horn operation, vehicle 

safety functions and vehicle light systems, to ensure proper 

operation. Ensure that the installation has not affected the 

vehicle operation or changed any vehicle safety function or 

circuit.

•  Scratched or dull reflectors, mirrors, or lenses will reduce 

the effectiveness of the lighting system. Avoid heavy 

pressure and use of caustic or petroleum-based products 

when cleaning the lighting system. Replace any optical 

components that may have been scratched or crazed during 

system installation.

•  Do not attempt to activate or deactivate the light system 

controls while driving in a hazardous situation.

•  Frequently inspect the light system to ensure that it is 

operating properly and that it is securely attached to the 

vehicle.

•  After installation and testing are complete, provide a copy 

of these instructions to instructional staff and all operating 

personnel.

•  File these instructions in a safe place and refer to them when 

maintaining and/or re-installing the product.

Failure to follow all safety precautions and instructions may 

result in property damage, serious injury, or death.

Содержание IPX6 IMPAXX

Страница 1: ...2562654C REV C2 0320 Printed in U S A Copyright 2011 2020 Federal Signal Corporation Installation and Maintenance Manual IPX6 IMPAXX Light Heads...

Страница 2: ...This limited warranty is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness for a particular...

Страница 3: ...troller 14 Configuring Multicolor Light Heads 15 Setting the White LEDs to Always Flash 15 Setting the Steady Burn Color 16 Setting a Multicolor Light Head to Flash One Color 17 Changing the Follower...

Страница 4: ...ller default settings 14 Table 3 Flash patterns for the IPX600 LED light head 24 Table 4 IPX600 replacement parts 27 Figures Figure 1 IPX600 mounted with bezel 19 Figure 2 IPX600 mounted without bezel...

Страница 5: ...uals when performing equipment installations on a vehicle Light Hazards To be an effective warning device this product produces bright light that can be hazardous to your eyesight when viewed at a clo...

Страница 6: ...the device and system amperage requirements Never attempt to install aftermarket equipment that connects to the vehicle wiring without reviewing a vehicle wiring diagram available from the vehicle man...

Страница 7: ...exist If the wiring is shorted to the vehicle body or frame high current conductors can cause hazardous sparks resulting in electrical fires or flying molten metal DO NOT install equipment or route w...

Страница 8: ...Scratched or dull reflectors mirrors or lenses will reduce the effectiveness of the lighting system Avoid heavy pressure and use of caustic or petroleum based products when cleaning the lighting syst...

Страница 9: ...ens and horns produce loud sounds that may cause in certain situations permanent hearing loss You and your passengers should consider taking appropriate safety precautions such as wearing hearing prot...

Страница 10: ...in transit If it has been damaged do not attempt to install or operate it File a claim immediately with the carrier stating the extent of damage Carefully check all envelopes shipping labels and tags...

Страница 11: ...to migrate in and out of synchronization IPX600 lights have the ability to have an external switch controller or controller steady burn override a single color by applying BAT to the OPTION wire This...

Страница 12: ...s in installing the lights are as follows 1 Optionally set a light head to control the flash patterns of one or more light heads in the IPX600 system See Converting a Light Head from Controller to Fol...

Страница 13: ...r emergency signaling purposes Failure to follow this warning may result in personal injury or death SET ONLY ONE CONTROLLER When putting together systems of IPX600 light heads ensure there is only on...

Страница 14: ...the green pattern selection wire to ground GND until the light head goes out and then flashes three times This procedure takes approximately 3 seconds Remove the green wire from GND shortly after the...

Страница 15: ...llower See Converting a Light Head from Controller to Follower on page 13 4 Apply 12 Vdc BAT to the white wire from the light head 5 Hold the green pattern selection wire to ground GND until the light...

Страница 16: ...above procedure to disable white LEDs from always flashing with the pattern If the OPTION wire is set for steady burn and there is more than one color in a light head you can change which color steady...

Страница 17: ...proximately 15 seconds Remove the green wire from GND shortly after the five flashes complete The multicolor light head now flashes one color Changing the Follower Power Up Color To change the power u...

Страница 18: ...or route wiring in the deployment path of an airbag Failure to observe this warning will reduce the effectiveness of the airbag or potentially dislodge the equipment causing serious injury or death V...

Страница 19: ...a 3 4 inch hole at the wire routing location 6 Prepare the hole for the wires by removing all burrs and sharp edges 7 Route the cable from the light head through the holes in the gasket and mounting s...

Страница 20: ...64 inch drill bit to drill two 0 172 inch holes at the scribed mounting hole locations 4 Drill a 3 4 inch hole at the wire routing location 5 Prepare the hole for the wires by removing all burrs and s...

Страница 21: ...electrical load the wiring and the connectors used in the circuit Failure to follow this notice could result in vehicle or equipment damage Make the connections shown in Figure 3 on page 22 synched or...

Страница 22: ...seal the green wire Synching and Alternating Light Heads If an IPX600 is set to be a follower and has more than one color you can change which color it will sync to on power up This provides a basic...

Страница 23: ...Black Black Fuse GND Follower Light Head Steady Burn Flash White Optional Power Configuring Light Heads for an X Flash Pattern To create an X pattern set one light as a controller and three lights as...

Страница 24: ...FPM 4 Single at 216 FPM 5 74 FPM Single 18 4 Single at 570 FPM 3 Single at 246 FPM 6 75 FPM Single 19 3 Single at 460 FPM 2 Quad at 75 FPM 7 240 FPM Single 20 Progressive flashes start slow and increa...

Страница 25: ...h to you or others CLEANING SOLUTION WARNING The use of cleaning solutions such as strong detergents solvents and petroleum products can cause crazing cracking of the domes and reflectors Failure to f...

Страница 26: ...ion test the emergency warning system to ensure that it is operating properly Also test all vehicle functions including horn operation vehicle safety functions and vehicle lighting systems to ensure p...

Страница 27: ...rer s Representative Provide a brief explanation of the service requested or the nature of the malfunction Address all communications and shipments to the following Federal Signal Corporation Service...

Страница 28: ...ral Signal Drive University Park Illinois 60484 www fedsig com Customer Support Police Fire EMS 800 264 3578 1 708 534 3400 Work Truck 800 824 0254 1 708 534 3400 Technical Support 800 433 9132 1 708...

Отзывы: