Ethernet-I/P Fieldbus Expansion Unit
PAGE 9
●
AFC3000 Ethernet-I/P System Signal Specifications (MASTER Spindle
→
→
→
→
PLC)
・
Number of MASTER Spindle Output Points 32 bytes (256 bits)
The table below is an example of the Output mapping using Ethernet I/P. Output bits (256) are
allowed to be user-programmed using the AFC3000 User Console Software.
The allocation of the signals can be set on any bit/pin through the “PLC Output Layout” setting function
of the AFC3000 Software.
Please refer to “5-3-4 PLC Output Layout” of the <<AFC3000 Operation Manual>> for list of available
output signals (Master and individual spindle signals)
EXAMPLE ONLY
: Actual signal placement may vary upon user configuration
Word No.
BIT
Signal
Word No.
BIT
Signal
Output word
No. 1
Output
Signal
Setting
Example
0 TOTAL REJECT
Output word
No. 3
Output
Signal
Setting
Example
0 SEQ No.17 SELECTED
1 TOTAL ACCEPT
1 SEQ No.18 SELECTED
2 TOTAL ABNORMAL
2 SEQ No.19 SELECTED
3 TOTAL READY
3 SEQ No.20 SELECTED
4 TOTAL BUSY
4 SEQ No.21 SELECTED
5 END
5 SEQ No.22 SELECTED
6 SEQ SELECT BIT 0
6 SEQ No.23 SELECTED
7 SEQ SELECT BIT 1
7 SEQ No.24 SELECTED
8 SEQ SELECT BIT 2
8 SEQ No.25 SELECTED
9 SEQ SELECT BIT 3
9 SEQ No.26 SELECTED
10 SEQ SELECT BIT 4
10 SEQ No.27 SELECTED
11 SPINDLE IN BYPASS
11 SEQ No.28 SELECTED
12 DATA AVAILABLE
12 SEQ No.29 SELECTED
13 CURRENT WARNING
13 SEQ No.30 SELECTED
14 CAL WARNING
14 SEQ No.31 SELECTED
15
ZERO LEVEL WARNING
15 SEQ No.32 SELECTED
Output word
No. 2
Output
Signal
Setting
Example
0 SEQ No.1 SELECTED
Output word
No. 4
Output
Signal
Setting
Example
0 REJECT No.1
1 SEQ No.2 SELECTED
1 ACCEPT No.1
2 SEQ No.3 SELECTED
2 ABNORMAL No.1
3 SEQ No.4 SELECTED
3 BYPASS No.1
4 SEQ No.5 SELECTED
4 REJECT No.2
5 SEQ No.6 SELECTED
5 ACCEPT No.2
6 SEQ No.7 SELECTED
6 ABNORMAL No.2
7 SEQ No.8 SELECTED
7 BYPASS No.2
8 SEQ No.9 SELECTED
8 REJECT No.3
9 SEQ No.10 SELECTED
9 ACCEPT No.3
10 SEQ No.11 SELECTED
10 ABNORMAL No.3
11 SEQ No.12 SELECTED
11 BYPASS No3
12 SEQ No.13 SELECTED
12 REJECT No.4
13 SEQ No.14 SELECTED
13 ACCEPT No.4
14 SEQ No.15 SELECTED
14 ABNORMAL No.4
15 SEQ No.16 SELECTED
15 BYPASS No.4