Ethernet-I/P Fieldbus Expansion Unit
PAGE 10
Word No.
BIT
Signal
Word No.
BIT
Signal
Output word
No. 5
Output
Signal
Setting
Example
0 REJECT No.5
Output word
No. 7
Output
Signal
Setting
Example
0 RUN REV HI REJ No.5
1 ACCEPT No.5
1 RUN REV LO REJ No.5
2 ABNORMAL No.5
2
LO CUR LIMIT WARNING No.5
3 READY No.5
3
HI CUR LIMIT WARNING No.5
4 BUSY No.5
4
CURRENT WARNING No.5
5 BYPASS No.5
5
CAL VOLTAGE WARNING No.5
6 TORQUE HOLD No.5
6
ZERO VOLT WARNING No.5
7 PAR SEL (BIT0) No.5
7
JUDGE COMBO (BIT1) No.5
8 PAR SEL (BIT1) No.5
8
JUDGE COMBO (BIT2) No.5
9 PAR SEL (BIT2) No.5
9
JUDGE COMBO (BIT3) No.5
10 PAR SEL (BIT3) No.5
10
JUDGE COMBO (BIT4) No.5
11 PAR SEL (BIT4) No.5
11
JUDGE COMBO (BIT5) No.5
12 TORQUE HI REJ No.5
12
JUDGE COMBO (BIT6) No.5
13 TORQUE LO REJ No.5
13
JUDGE COMBO (BIT7) No.5
14 FTQ HI REJ No.5
14
JUDGE COMBO (BIT8) No.5
15 FTQ LO REJ No.5
15
Output word
No. 6
Output
Signal
Setting
Example
0 SNUG TQ HI REJ No.5
Output word
No. 8
Thru
No. 16
Output
Signal
Setting
Example
0
1 TQ INHIBIT HI REJ No.5
1
2 F ANGLE HI REJ No.5
2
3 F ANGLE LO REJ No.5
3
4 DIFF + ANG REJ No.5
4
5 DIFF – ANG REJ No.5
5
6 RATE 1 HI REJ No.5
6
7 RATE 1 LO REJ No.5
7
8 RATE 2 HI REJ No.5
8
9 RATE 2 LO REJ No.5
9
10 RATE 3 HI REJ No.5
10
11 RATE 3 LO REJ No.5
11
12 1
ST
TIME HI REJ No.5
12
13 1
ST
TIME LO REJ No.5
13
14 2
ND
TIME HI REJ No.5
14
15 2
ND
TIME LO REJ No.5
15
The example above (output word 5-7) shows an example of all available signals for each spindle.
While normally not all signals are used, any of the signals (for each spindle) can be preset
(programmed using the AFC3000 software) to any output bit.
* The word No. at the PLC input side differs according to the setting of the node address, etc., so please be
sure to confirm before using. Please refer to the AFC3000 Operation Manual, Section 5-3-2 and 5-3-3 for
description of the respective signals.
The unused area of Word 01 to 16 is also secured.