Ethernet-I/P Fieldbus Expansion Unit
PAGE 11
Fieldbus Setting (Ethernet-I/P)
The fieldbus settings are set in the “Fieldbus Setting” menu of the AFC3000 User Console. The following
setting window is displayed when “Multi”
→
“Fieldbus Setting” is selected at the menu bar.
In the Bus Type Select/communication window, selection of the fieldbus type, uploading, downloading,
and verification of fieldbus settings with respect to the Unit, and browsing and saving of fieldbus settings
with respect to the PC can be performed.
-
The standard set values are set as the factory settings in the
Unit. Do not change the settings unless there is a special
reason.
-
Be sure to perform backup before changing the fieldbus
settings of the Unit.
●
Bus Type Select: The type of bus is selected from the list. Also, when ”Upload” is executed, the bus
type is judged automatically and reflected in the selection part.
●
Configuration File
・
Browse: A fieldbus configuration file (*.nrfcf) is read from the PC.
・
Save: A fieldbus configuration file (*.nrfcf) is saved in the PC.
●
Upload:
The fieldbus settings are read from the MASTER Spindle for PC communication
and I/O (PLC) control.
●
Download:
The fieldbus settings are written into the MASTER Spindle for PC communication
and I/O (PLC) control. (Re-activate the control power after writing.)
●
Verify:
The fieldbus settings of the MASTER Spindle for PC communication and I/O
(PLC) control and the fieldbus settings in the User Console are compared.