background image

P.O. Box 100  •  Hildebran, NC 28637  USA  •  828-397-4200  •  828-397-4415 FAX
http://www.elkproducts.com  •  email:  [email protected]

APPLICATION

The ELK-P412 is a general purpose high current power supply and battery charger. It is ideal for alarm, access control,
and CCTV applications requiring up to 4 Amps. The ELK-P412K is packaged complete with enclosure, battery, and AC
power cord. It distributes 12 Volts D.C. power to three (3) sets of DC power terminals, each having a voltage present
indicator LED and automatic resetting overload protection. Built-In Low Battery Cut-off circuit protects the battery from
deep discharging if AC power is lost for an extended period of time.

Power Supply

 4 Amp, 12 Volt DC Power Supply &

Battery Charger with Enclosure

12 Volt Battery

(Included with ELK-P412K)

AC

INPUT

BLACK

NEG

BA

T

T

E

R

Y

+

-

POWER
ON

POWER ON LEDS

L N

-V +V

DC

OUTPUT

EARTH

GROUND

4 AMP POWER SUPPLY

POWER
OFF

SW1

14

.5

V

DC I

N

+

-

RED

+12V

OUTPUT 1

NEG

+12V

OUTPUT 2

NEG

+12V

OUTPUT 3

120VAC POWER CORD (6')

GRD

NEUTRL

LINE

Before plugging

in the power

cord, replace the

snap-on cover

over the AC

terminals for

shock

protection

AC

POWER
ON LED

DO NOT ADJUST

(FACTORY SET)

LOAD 1

LOAD 2

LOAD 3

WARNIN

G SHOCK

HAZARD

FILE  E127738

INSTALLATION / OPERATION

1. Set Master Power Switch (SW1) to Power Off.
2. Mount enclosure in secure location near an AC power

outlet that is not controlled by a switch.(supplied
power cord is 6 feet long)

3. Connect devices to be powered to the screw

terminals for DC output.The power distribution board
has three sets of outputs, each set is limited to 2.5
amps. If a device requires more that 2.5 Amps, parallel
two sets of terminals. (DO NOT EXCEED 4 AMPS)

4. Connect Battery to the battery wires, observe polarity.
5. Plug in the AC cord. 

Warning High Voltage

 is now

present at the power supply AC input terminals.

6. Set the Master Power Switch to Power On. The LEDs

at the power outputs should be on (if any are off,
check for overloaded condition). The connected
devices are now powered.

7. If AC power is lost, the Low Battery circuit will

disconnect the battery if it's voltage drops below 10
Vdc. This helps to prevent "deep discharging" of the
battery.

FEATURES

Switching Power Supply, no transformer needed.

Regulated 12VDC Output, capable of delivering 4 Amps.

Automatic Resetting Overload Protection.

Three Individually PTC Fused (2.5A) DC Power Outputs.

Master AC and Battery ON / OFF Power Switch.

Visual AC and DC LED Power Indicators.

Built-In Battery Charging Circuit.

Includes (1) Six foot AC Power Cord and cable clamp.

Heavy Duty Enclosure.

ELK-P412K includes (1) 12v Battery.

Lifetime Limited Warranty, call for details.

Automatic Low Battery Cutoff Circuit Protects Battery
from Deep Discharge.

SPECIFICATIONS

DC Output Voltage: 13.8 Volts D.C.

Current Rating: 4 Amps .

Auto Resetting "fuseless" circuit breakers (PTC).

AC Input Voltage Range: 85~264VAC @ 47~63Hz.

Low Battery Cutoff: ~=10 Volts.

Ripple & Noise: 100mVp-p.

Enclosure Dimensions: 12.5"H x 7.5"W x 3.75"D.
 

Features and Specifications subject to change without notice.