CPC505
C P C 5 0 5 U s e r M a n u a l
53
© 2 0 2 2 F a s t w e l v . 0 0 1
strongly advised to make sure that the operating environment of the CPC505 meets the
temperature requirements.
9.2 Operating conditions and MTBF
The device must be able to withstand the following climatic and mechanical actions:
Table 9
–2 – Environmental exposure when operating CPC505
Type of impact
Parameter name
Parameter value
Document
Temperature change at up to 80% relative
humidity, non-condensing
Low temperature
- 40
°С
GOST 28209-89
(IEC 68-2-14-84)
High temperature
+ 85
°С
Sinusoidal vibration
Range of frequencies
(Hz)
10...500
GOST 28203-89 (IEC
68-2-6-82)
Acceleration, g
2
Single shocks
Peak acceleration, g
30
GOST 28213-89 (IEC
68-2-27-87)
Multiple shocks
Peak acceleration, g
10
GOST 28215-89 (IEC
68-2-29-87)
Number of shocks
1000
Modules are resistant to cyclic damp heat at ambient temperature of + (55
±2) °C, relative humidity
(93
±3) % (with conformal coating: option \Coated) in accordance with GOST 28216-89 (IEC 68-2-
30-82).
The MTBF (Mean Time Between Failure) of the CPC505 is at least 50,000 hours.