-83-
•
Alarm reset
Always reset an alarm after ensuring safety by removing the cause of the alarm and turning the
operation signal OFF.
•
Alarm release
Always release an alarm after ensuring safety by removing the cause of the alarm and turning the
operation signal OFF.
•
Alarm release method
- After the operation swich is set to “STAND-BY”, it can be released by pressing the “S” button.
- Turn off the power, wait for at least 1 minute, and then cycle the power.
Attention
• If the product dose not operate properly after the power is cycled, the
internal circuit may be damaged. Contact your nearest sale office.
• Continuing the operation without removing the cause of the alarm may cause
malfunction of the equipment.
• Reset using the ALARM-RESET input
Turn the operation signal OFF and then turn ALARM-RESET input ON (Keep it ON for 10 msec or
more). The ALARM-RESET input is disabled while the operation signal is being ON. The figure
showns an example for which the operation signal is the FWD input.
•
Alarm records
Up to 10 generate alarms to save in NVM (Non-volatile memory) in order of the latest to oldest.
When clearing the alarm records, perfrom the alarm record clear on the monitor mode.
Содержание Ezi-SPEED ESD-30-C
Страница 1: ......
Страница 9: ...9 2 Characteristics 2 1 Part number...
Страница 15: ...15 3 2 Dimensions 30W 60W 120W Drive 200W 400W Drive...
Страница 18: ...18 ESM 90 H 120 ESM 104 H 200 ESM 104 H 400...
Страница 19: ...19 4 3 Characteristics of motor torque 30W 60W 120W...
Страница 20: ...20 200W 400W...
Страница 63: ...63 8 2 Setting and 7 segments display 1 Monitor mode...
Страница 64: ...64 2 Input Output setting mode...
Страница 65: ...65 3 Parameter setting mode 1page...
Страница 66: ...66 3 Parameter setting mode 2page...
Страница 67: ...67 3 Parameter setting mode 3page...
Страница 68: ...68 3 Parameter setting mode 4page...
Страница 69: ...69 4 NVM saving mode...