![Fastcorp F820 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/fastcorp/f820/f820_service-and-parts-manual_3567549004.webp)
4
must be discarded and proper cleaning procedures must be taken.
The screen will read “
Health Sensor Active
”. It will not operate until both the RESET button is pressed and
the freezer temperature has returned to safe levels. The machine is set not to accept money if the freezer
has not reached proper operating temperatures. If the machine must be operated, even though the freezer is
not at an acceptable temperature, you can bypass the heath sensor.
REMOVING THE CONTROL CONSOLE
During initial placement or transporting, it may be necessary to remove the control console in
order to fit the machine through narrow doorways.
1. The cover from the computer board can be removed one of two ways:
2. Loosen three (3) ¼” head screws. Lift the cover up and off. Remove one (1) of the two (2) 3/8”
head bolts holding the top of the console onto the cabinet
3. Remove the top two (2) 3/8” head bolts and loosen the bottom 1/4” head bolt. Lift the cover up
and off. Reinstall one (1) of the 3/8” head bolts. Leave one (1) of the bolts in place to prevent the
console from accidentally falling.
4. With a permanent marker, number each of the FFC cables with the corresponding connector
number printed on the
intermediate board (J-24, J-25….)
. Mark the 2-pin connector, which plugs into
J-28 (VAC sensor, below the ground wire). Remove the 2-pin connector and all cables from the
board.
5. Label and remove the following connectors from the computer board:
6.
J-15 Door (2 pin, top left, twisted wires)
7.
J-4 Triac (left side lower, 12 pin w/wires at location 1 and 12 only)
8.
J-I Power (4 pin, bottom left)
9.
J-11MDB (J11, 6 pin, right side, middle, white connector/white wires
10. Remove the coin box and remove the bottom two (2) 3/8” heads bolts with 7/16” nuts that
hold the console to the cabinet.
11. Pull the cables and wires through the holes, out the back of the console. Remove the wiring
harness from the retainers on the back of the console. Cut tie wraps as needed making note of
their location so that they can be accurately replaced during reassembly.
12. Loosen the three (3) bolts that hold the back of the console to the side of the cabinet. The
holes are slotted and do not require complete removal.
13. While supporting the console, remove the top bolt (originally left in to prevent the console
from accidentally falling). Remove console.
14. To reinstall console, reverse steps. Make sure that wires, cables and harnesses are properly
connected. Replace original wire ties.