10
allow menu selections to be vended without money and without affecting sales meters. Test
each bin selection. Press “Free Vend” again to deactivate this feature.
“Test Vend” on the service keypad allows money to be inserted in order to test menu selections
without affecting sales meters. Money deposited will be returned after each test vend. Press “Test
Vend” again to deactivate this option.
PROGRAMMING/EDITING AFTER THE MACHINE HAS BEEN OPERATING
1) After
the
machine
has been programmed and operating in the field, any sold out or bin errors
that have occurred will be displayed once the door is opened (Service Mode). A bin error
occurs if the robot has made three unsuccessful attempts to retrieve a product from a single
bin. An “Out Of Product” is displayed when a bin is determined empty.
2) Do not press “* Exit” before viewing all bin errors. To scroll through the list of all bin errors
including selection and bin number, use the “#Next” key on the customer keypad.
NOTE: it is
important to view all before loading or editing of bin selections
3) Perform a “Free Vend” on these bins to verify that the robot was programmed over the center
of the product and that product was loaded properly.
4)
To clear all bin errors and “Out Of Product” bins, press “Load” and then “Close” on the
service keypad. The display must be in the main menu for this to work (ie. 1) CHANGE
PRICE).
5)
The
machine
is ready to be edited and/or loaded with product.
MENU ITEM PROGRAMMING SEQUENCE
1) CHANGE PRICE -
Changing the price of programmed selections.
Display
Programming Instructions
1) CHANGE PRICE
* = Next
Menu
# = Yes
a) Press the #=Yes key.
Edit Selection
#:_ _
* = Exit
b) Enter the selection number.
A1 Price:
$1.00
*=Abort
#=Yes
c) Type over the price.
A1 Price: $
1.50
Accept? *=No
#=Yes
d) Press the #=Yes key to enter the price
change.
2A) SALES METERS -
Choose from two types of sales meters: (a) Non-Resetable (total cash
and unit meter that cannot be reset) and (b) Resetable (offers individual and total sales by
product which can be cleared/reset).
Display
Programming Instructions
2) SALES METERS
* = Next
Menu
# = Yes
a) Press the #=Yes key.
Choose Meter Type
* = Total
# = Resetable
b) The Total Meter is a non-resetable sales and
unit counter.
Total = $1575.30
Units = 975
#=Exit
c) Press the #=Exit key to exit and return to
SALES METERS.
2B) RESETABLE SALES METERS
Display
Programming Instructions
2) SALES METERS
* = Next
Menu
# = Yes
a) Press the #=Yes key.
Choose Meter Type
* =
Total #
=
Resetable
b) The # key to enter resetable meter
A1: $50.00 25
*Scroll
#Next
c) Press * Scroll key to view each selection’s
sales or # Next key to view total sales.
$ 10,250
5,000
d) Press the *= Clr key to clear the meter or
Содержание F820