![FAST AG Solutions Fast Sprayers 9500 Series Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/fast-ag-solutions/fast-sprayers-9500-series/fast-sprayers-9500-series_operators-manual_3536051074.webp)
5.2.2 TANK CLEANING
A.
Daily Cleaning
At the end of the working day, clean the system
using this procedure:
1. After the chemical solution has been com-
pletely sprayed out through the booms, add
20 gallons (75 liters) of clear water to the tank.
2. Run at rated speed to force the solution
through the agitator jets and wash head(s).
Run for 5 minutes.
3. Spray the rinse lightly over previously sprayed
crop.
4. Add another 30 gallons (200 liters) of clean
water and run rinse/wash cycle for 5 minutes.
5. Flush the rinse solution out of the booms to
clean the hoses and plumbing over the
appropriate crop.
6. Rinse the system again with clean water.
7. Clean the screen and nozzles.
8. Drain tank and let dry.
B.
Changing Chemicals and/or Annual
Wash to Remove Salt and Amine
Formations
1. Do the rinse procedure outlined for Daily
Cleaning.
2. Add 50 gallons (200 liters) of clean water to
the tank.
3. Remove nozzles and screen and wash
separately.
4. Add 1/2 gallon (2 liters) of household ammo-
nia to the tank (1 part ammonia to 100 parts
water).
5. Run rinse/wash cycle for 5 minutes.
6. Spray half the solution out the boomsover the
appropriate crop .
7. Let the balance sit for a minimum of 8 hours,
overnight is best.
8. Run wash cycle for 10 minutes and spray
solution out the booms on the appropriate
C.
Changing Chemicals and/or Annual
Wash to Remove Esters of 2, 4-D and
MCPA Formations
1. Do the wash and rinse procedures outlined for
Daily Cleaning.
2. Add 50 gallons (200 liters) of clean water to
the tank.
3. Remove nozzles and screen and wash
separately.
4. Add dishwasher detergent to the tank (2lbs./
50 gal or 1 kg/300 l of water).
5. Run rinse/wash cycle.
6. Spray the solution out the booms on the
appropriate crop and drain thoroughly.
7. Add 50 gal (200 l) of clean water to the tank.
8. Add 1/2 gal (2 l) of household ammonia to the
tank (1 part ammonia to 100 parts of water).
9. Run wash cycle.
10. Spray 1/2 the solution out the booms.
11. Let the balance sit for a minimum of 8 hours,
overnight is best.
12. Run rinse/wash cycle for 10 minutes and
spray out the booms on the appropriate crop.
13. Rinse the system thoroughly with clean water
and flush out the booms.
14. Drain the entire system and let dry.
69
WARNING
Do not enter tank at any time.
crop.
9. Rinse the system thoroughly with clean water
and flush out the booms over the appropriate
crop .
10. Drain the entire system and let dry.
Содержание Fast Sprayers 9500 Series
Страница 68: ...63 Fig 62 BOOM TILT PIVOT 3 Grease boom tilt pivot 1 location each boom Left Right...
Страница 78: ...73 This page left blank...
Страница 88: ...7 4 CHEMICAL CIRCUIT SCHEMATIC 82...
Страница 89: ...7 5 ELECTRICAL SCHEMATIC CABLE 10 CONSOLE 3 OR 6 BOOM SCS 440 450 CONSOLES...
Страница 90: ...CABLE 33 FLOW CONTROLLER 3 OR 6 BOOM VALVES 84...
Страница 92: ...86 7 7 9500 SERIES 5 FUNCTION HYDRAULIC CAB BOX 9600 SERIES 60...
Страница 93: ...7 8 9500 SERIES 5 FUNCTION CAB BOX WIRING 9600 SERIES 60...
Страница 94: ...7 9 9600 SERIES 80 100 6 FUNCTION HYDRAULIC BLOCK 88...
Страница 95: ...7 10 9600 SERIES 80 100 6 STATION CAB BOX...
Страница 96: ...7 11 9600 SERIES 80 100 6 STATION CAB BOX WIRING 90...
Страница 97: ...7 12 PARTS LIST FOR YAW BLOCK 91 7 12 9500 SERIES 120 132 YAW BLOCK...
Страница 98: ...7 13 9500 SERIES 120 132 YAW BLOCK HARNESS 92...
Страница 99: ...7 14 9500 SERIES 120 132 YAW CAB BOX...
Страница 100: ...7 15 9500 SERIES 120 132 YAW CAB BOX WIRING 94...
Страница 102: ......
Страница 103: ......