10 mm @ 3 m distance
35 mm @ 5 m distance
100 mm @ 10 m distance
Typical field of view (HxW):
420 mm x 550 mm @ 0.5 m
930 mm x 1170 mm @ 1 m
1880 mm x 2160 mm @ 2 m
2740 mm x 3160 mm @ 3 m
3600 mm x 4160 mm @ 4 m
4470 mm x 5150 mm @ 5 m
Compensation:
Optional user compensation with supplied reference plate
Scan volume
39.5 m
3
(at max range 5 m)
Light source:
In-built LED flash
Laser (Optical Transmitter)
Eye safety:
Laser class 1
Pulse duration:
≤ 7 ms
Wavelength:
798 nm to 816 nm
Cameras
Recorded 3D points
a
:
Up to 220,000 points/s, point cloud density increases with
time
Best points filter
b
:
Noise reduction of typically 40% when scanning the same
object from different distances
Exposure time:
0.1 ms to 7 ms (auto exposure)
Texture color:
24 bit
Lighting conditions
c
:
Full daylight, 10,000-45,000 Lux
(reduced performance in direct sunlight)
a
Point density depends on scanned surface and lighting conditions.
b
Noise reduction for equal scan times at 0.5 m, 1 m, 2 m and 3 m distance from object.
c
Limited range and point density in sunlight.
FARO Freestyle 2 User Manual
Appendix C: Technical Data
FARO Freestyle 2 (August 2020)
Page 52 of 58