6.3.4
EMERGENCY
A defect in the electrical installation or power supply of the tractor is considered an emergency. When the system
is completely disconnected, switched off or defective, it is always possible to control the circuit of the
support
leg
(set as default, with a reversed switching function)
Manual emergency control
•
The distributor can be controlled mechanically in emergency
•
The control is performed by manually pressing the slide valve of the distributor over the spring (e.g.,
using a suitable rod with a diameter of about 3 mm)
•
For this purpose, there are holes on the bottom of the distributor
•
Example:
Controlling the “frame folding” circuit
•
Close the circuit by
pushing the slide valve for the “support leg”
(the slide valve has an
opposite function, the circuit is open without voltage)
•
Open the circuit for “frame folding” by pushing the slide valve
•
Control the selected circuit with oil pressure from the tractor
Emergency circuit