Manual
EXCELENT Premium 6; 8
20
│
52
3.6.2
Proper connection to the tractor
For proper connection, the following facts must be observed:
Outlet hose
-
Do not connect the outlet hose to the tractor distributor! (pressure in the reverse branch would thus be
increased)
-
Large quick coupling on the outlet hose must not be confused with the small one
-
Oil returning through the outlet pipe must not be throttled anywhere
-
Maximum allowed pressure value in the outlet hose is 5 bar
, higher pressure pushes the shaft seal out,
which causes damage to the hydraulic motor fan
Pressure hose
-
Connect the pressure hose to the circuit giving priority to the oil supply
Picture 24.2 – Position of quick couplings in the tractor
1.
Connecting the outlet hose
Connect the outlet hose (outer
⌀
27 mm) with the large quick coupling to the free drain to the tractor tank.
In case that there is no free drain to the tank attached to the tractor as standard, please contact the
tractor manufacturer (dealer) for information regarding the possibilities of a free drain end piece.
Picture 24.3 – Outlet hose connection
Free drain to the tank
Tractor distributor