26
Break - In Checklist
Note:
The break-in period is different from normal
operating conditions.
The tube and flighting must get a polished surface
through use. Once the new auger has polished it
will run smooth at recommended speed.
Note:
Never operate an empty auger for over one
minute, as the flighting and housing will
experience excessive wear.
During the break-in-period:
1. Run the tractor at slow idle until grain begins to
flow from the discharge. For the first 500 bushels,
operate at the slow speed and restrict the flow of
grain at the intake.
2. Gradually increase the speed until operating at full
PTO speed.
Note:
Do not run empty during break-in period.
WARNING
AVOID INJURY OR DEATH
•
Disengage the PTO, engage the machine’s parking
brake, stop the engine and make sure all rotating
components are completely stopped before
connecting, disconnecting, adjusting or cleaning
any PTO driven equipment.
•
Always keep PTO shields and all guards in place
when using PTO driven equipment.
•
Disengage PTO for road travel.
•
Keep hands, feet and clothing away.
Check the following mechanical items after 1 hour
of operation and again after 10 hours of operation:
1. Re-torque wheel bolts to proper torque and check
tire pressure.
2. Check for loose fasteners and hardware. Tighten as
required.
3. Check the condition of all hydraulic lines, hoses,
fittings and couplers for damage or leaks.
4. Tighten leaking fittings and repair or replace any
damaged components.
5. Check the condition of all electrical lines, wires,
and connections. Repair or replace any damaged
systems or components.
6. Check that all guards and shields are in place,
secured and functioning as designed.
WARNING
ROTATING PART HAZARD
To prevent serious injury or death from rotating
parts:
•
Place all controls in neutral or off, stop engine or
motor, remove ignition key or disable power source
and wait for all moving parts to stop before servicing,
adjusting, repairing or unplugging.
•
Install and secure all guards / shields before
operating.
•
Do not operate with rotating parts exposed.
Содержание 1684
Страница 1: ...052020 FK420 OPERATOR AND PARTS MANUAL 16 BACKSAVER AUGER Models 1684 16104 16124...
Страница 2: ......
Страница 4: ...1684 16104 16124 Backsaver Auger 2...
Страница 6: ...Warranty Registration Form 1684 16104 16124 Backsaver Auger 4...
Страница 8: ...Introduction 1684 16104 16124 Backsaver Auger 6...
Страница 12: ...Introduction 1684 16104 16124 Backsaver Auger 10...
Страница 14: ...Safety 1684 16104 16124 Backsaver Auger 12...
Страница 24: ...Safety 1684 16104 16124 Backsaver Auger 22...
Страница 26: ...Operation 1684 16104 16124 Backsaver Auger 24...
Страница 48: ...Operation 1684 16104 16124 Backsaver Auger 46...
Страница 50: ...Maintenance 1684 16104 16124 Backsaver Auger 48...
Страница 91: ...Parts Identification 1684 16104 16124 Backsaver Auger 89...
Страница 128: ...Parts Identification 1684 16104 16124 Backsaver Auger 126 HYDRAULIC HOPPER MOVER WINCH 1684 16104 A B C D E 1 917935...
Страница 138: ...Parts Identification 1684 16104 16124 Backsaver Auger 136...
Страница 140: ...Specifications 1684 16104 16124 Backsaver Auger 138...
Страница 143: ...Specifications 1684 16104 16124 Backsaver Auger 141...
Страница 144: ...Specifications 1684 16104 16124 Backsaver Auger 142 DIMENSIONS 1684 16104 Models A D E G F H I J K C B...
Страница 146: ...Specifications 1684 16104 16124 Backsaver Auger 144 16124 Models A D E G F H I J K C B...
Страница 149: ...Specifications 1684 16104 16124 Backsaver Auger 147 HARDWARETORQUE VALUES Metric Chart...
Страница 150: ...Specifications 1684 16104 16124 Backsaver Auger 148 Imperial Chart...
Страница 152: ...Specifications 1684 16104 16124 Backsaver Auger 150...
Страница 154: ...Warranty 1684 16104 16124 Backsaver Auger 152...
Страница 157: ......