Vacuum Valve Removal
1.
In case of removing the Vacuum Valve for whatever
reason, follow the steps below:
a.
Remove the Vacuum Valve from its port using
the Multi purpose key.
a.
Install the M16 Cap included in the
package on the Vacuum Valve port by
screwing it all the way in (image #28).
Make sure the cap has an O‐ring around its
thread prior to installation.
Image #28
Once the Vacuum Valve has been removed and an M16 port cap has been
installed on the port, it important to carry out the first dive with the housing
empty (no camera installed inside) in order to verify that the housing
watertight seal has not been affected during the replacement.
The Vacuum Valve port was designed to accommodate the Vacuum Valve
only and any other components should not be installed on this port.