How to Wire Your Ceiling Fan
1. Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the supply grounding conductor (this may
be a bare wire or wire with green colored insulation).
Securely connect wires with wire connectors supplied.
(Figure 14)
HOUSEHOLD
SUPPLY
LISTED
OUTLET BOX
BLACK
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND)
BLACK FAN
WIRE
WHITE
BLUE
GREEN WIRE
(GROUND) FROM
HANGER BALL
Installing the Canopy Housing
WARNING
To avoid possible
fi
re or shock, be sure electricity is
turned off at the main fuse box before hanging.
(Figure 13)
Figure 13
MAIN FUSE BOX
2. Securely connect the white fan motor wire to the
white supply (neutral) wire using wire connector
supplied. Securely connect the black fan motor wire
and blue wire to the black supply wire using wire
connector supplied. (Figure 14)
Figure 14
HARDWARE USED:
WIRE
CONNECTORS
X 3
Household
Supply
Listed
Outlet Box
Black Wire
from Supply
Green Wire
(Ground) from
Hanger Bracket
Green Wire
(Ground) from
Supply
White Wire
from Fan
Blue Wire
from Fan
Green Wire
(Ground) from
Hanger Ball
Black Wire
from Fan
White Wire
from Supply
Figure 15
3. After splicing and making the wire connections, the
wires should be spread apart and turned upward with
the grounded conductor and the equipment-grounding
conductor on one side of the outlet box and the
ungrounded conductor on the other side of the outlet
box. (Figure 15)
WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not operate
fan until the blades are in place. Noise and fan damage
could result.
1. Remove one of the two shoulder screws in the
hanger bracket. Loosen the second shoulder screw
without fully removing it. Assemble canopy by
rotating key slot in canopy over shoulder screw in
hanger bracket. Tighten shoulder screw. Fully
assemble and tighten second shoulder screw that
was previously removed. (Figure 16)
WARNING
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the canopy
housing and not pinched between the housing and the
ceiling.
NOTE: This step is applicable after the neccessary wiring is completed.
Figure 16
Ceiling Canopy