PROG 1

     HEATING mode

Regulator work with sensor  C1 which have definited temperature 
T1 and  hysteresis H1. 

PROG 2

  COOLING mode

Regulator work with sensor  C1 which have definited temperature 
T1 and  hysteresis H1. 

T1

T1-H1

P1

P2

C1

T1+H1

If temeprature on output relay C1 fall under value   (T1+H1), it 
cause close a joint  P1 and P2 in the same time. Joints P1 and P2  
will be open if temperature on input sensor C1cross value (T1+ 
H1).

T1

T1-H1

T1+H1

P1

P2

C1

Relays  P1 and P2  work in parallel connection and closing joints 
when temperature is higher than value(T1+H1). Joints of realys 
will be open when temperature fall under value   (T1-H1).

PROG 3

     HEATING/COOLING mode

Regulator  work  with  sensor    C1  which  have  definited 
temperature T1 and  hysteresis threshold H1. 

PROG 4

      HEATING mode- two regulators

Regulator  works  with  sensors  C1  i  C2  in  function  two 
independent  thermostat  which  works  in  heating  mode.  For 
sensor C1 is definited temperature T1 and  hysteresis threshold 
H1, but  for sensor C2 is definited temperature T2 and  hysteresis 
threshold H2.  

T1

T1-H1

T1+H1

P1

P2

C1

Relays P1 and P2 works alternately. P1 work in cooling mode, 
closing  joint  when  teperature  fall  under  value    (T1    H1)  and 
opening it when cross value (T1 + H1). Realy P2 work in heating 
mode, closing joint when temperature fall under value (T1- H1) 
and returnly opening it when cross value  (T1 + H1).

P1

P2

T1

T2

T1-H1

T2-H2

C1

T1+H1

T2+H2

C2

PROG 5

       COOLING mode- two regulators

Regulator  works  with  sensors  C1  and  C2  in  function  two 
independent thermostat which works in cooling mode. For sensor 
C1 is definited temperature T1 and  hysteresis threshold H1, but  
for  sensor  C2  is  definited  temperature  T2  and    hysteresis 
threshold H2.  

If  temperature  of  sensor    C1  fall  under  value  (T1-H1),  it  caue 
close a joint P1. When temperature increase higher than value 
(T1+H1), than joint P1 will be raturnly open. Similary for sensor   
C2  when temperature  will be smaller than (T2-H2) than joint P2 
will be close, returnly opening will be possible than temperature 
cross value (T2+H2).

T1

T2

T1-H1

T2-H2

2

T1+H1

T2+H2

P1

P2

C1

C2

If temperature from sensor C1 increase higher than value (T1 + 
H1), then joint P1 will be closed. But when temperature fall under 
value (T1 - H1), than joint P1   will be returnly open. Similary for 
sensor C2, when temperature will be higher than value (T2 + H2) 
tham  joint  P2  will  be  closed.  It  will  be  returnly  open  when 
temperature fall under  value (T2 - H2).

Содержание CRT-06

Страница 1: ... panel for programming and monitoring 10 operation functions 2 independent temperature sensors two independent temperature values may be set 2 x 1Pcontacts applied to the temperature sensors 2 hysteresis set values one for each sensor AUTOMATIC mode operation with one selected function MANUAL mode permanent closing or opening of the contact without a temperature measurement Separate temperature dr...

Страница 2: ...et of output relays independent of reports from sensors 5 In automatic work will dispalied menu to select program one of tenth saved in device memory OK OK Menu Menu Info MENU System MENU Settings MENU Tryb MENU Mode MENU ATTENTION Choose handwork mode is signalize by sign R near sings which present position of relays P1 ON joint of relay P1 is close but joint of relay P2 is open P1P2 ON joints of...

Страница 3: ...nited temperature T2 and hysteresis threshold H2 T1 T1 H1 T1 H1 P1 P2 C1 Relays P1 and P2 works alternately P1 work in cooling mode closing joint when teperature fall under value T1 H1 and opening it when cross value T1 H1 Realy P2 work in heating mode closing joint when temperature fall under value T1 H1 and returnly opening it when cross value T1 H1 P1 P2 T1 T2 T1 H1 T2 H2 C1 T1 H1 T2 H2 C2 PROG...

Страница 4: ...ow mode two sensors Regulator works with two sensors C1 and C2 If temperature from two sensors will be in range which is definited by values T1 iandT2 then relay joints P1 and P2 will be closed C1 P1 P2 T1 T2 ATTENTION When will set value T2 T1 then regulator will be work correct PROG 10 Window mode two regulators Device works as two independent thermostats which works in window mode Sensor Czujni...

Страница 5: ...cision 1 C Ordered value of temperature T3 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 100 400 C with precision 1 C Ordered value of temperature T4 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 100 400 C with precision 1 C Value of hysteresis for temperature T1 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 1 100 C with precision 1 C Value of hysteresis for temperature ...

Страница 6: ...OK Menu Menu Menu Menu ATTENTION Work in safe mode is signalize by dispalied a sign In this cause pass to setting of regulator press button MENU is previuos by key correct a pin code Example of key PIN code 6 System Password This parameter is use to safe acces for all user to menu Password is a number from range 0 to 999 but save password to 0 unlock a menu Set password another than 0 cause pass t...

Страница 7: ...t NO Default sett YES Saved YES ATTENTION Return to default settings cause delete all earlier configurations with saved programs Rest of parameters of regulators are set with values Menu Info This Menu Info is use to display max and min values which were registered by temperature sensor OK OK Hi 54 Lo 23 Info MENU Code 01 Error Code 02 Error Error codes Wrong work of regulator is siganalize by bli...

Страница 8: ...ll cause break contolled device or menace for user In this cause producer is not responsible of arise accidents and could refuse given warranty for regulator in cause submit a claim A090706 sensor PT100 dimensions of sensor Ø4 h 85mm sensor isolation steel bush cable PC 3 0 34mm l 1 5m PROBE RT56 TECHNICAL DATA supply 230V AC current load 2 16A joint separated 1P range of regulation temperature 10...

Страница 9: ...01 0100 10 120 TCN4L 22R TX4H 14R TX4H 24R TX4H A4R TX4H B4R TX4L 14R TX4L A4R TX4L B4R TX4M 14R TX4M 24R TX4M A4R TX4M B4R QP99 CP 02 CP82 CP99 R38 LAOO R38 LARR 72 11304023 0150 0050 72 11304027 0150 0050 72 23304003 0150 0050 GGP 72 23904001 0300 0040 TM 72 34904001 0300 0040 TM TEM 73 A AT403 414 1000 AT403 614 1000 AT 503 1141 000 AT 503 1161 000 AT 503 6140 000 AT 603 1141 000 AT603 414 1000...