background image

Pass to programming mode is possible by push button MENU.

Structure of main menu:

PROGRAMMING

To select position  from  menu we use buttons “UP” and “DOWN”. 
If you want pass to selected position then you need push button 
OK. Pass to main menu is possible by push button  return.

Menu -> MODE

Instruction to select work mode: :
1. By button  Menu pass to main menu.
2. Prees button  OK.,to   entered pass to menu. 
3. By buttons “UP”  or “DOWN” select work mode: HADWORK or 
AUTO, enter by OK.
4. If will choosen hadnwork mode, wil displaied additional menu 
to set position outout of relay (open or close).  Select by buttons 
“UP”   or “DOWN” and enter by OK. Pass to main menu without 
save all settings  is possible by push button  return.

This mode is use to set mode of work: automatic or handwork. In 
automatic work position of output relay is depend of reprts from 
sensors which are connect to regulator and executed program.   
Hadwork mode make possibility set of output relays independent  
of reports from sensors.

5. In automatic work will dispalied menu to select program ( one of 
tenth) saved in device memory. 

OK

OK

Menu

Menu

Info

 

MENU

System

 

MENU

Settings

 

MENU

Tryb

 

MENU
Mode

 

MENU

ATTENTION!:

 

Choose handwork mode is signalize by sign R near sings which 
present position of relays.

P1 ON - joint of relay P1 is close, but joint of relay P2 is 
open.

P1P2 ON - joints  of  relays P1 and P2  are close. 

P2 ON - joint of relay P1 is open, but joint of relay P2 is 
close.

P1P2 OFF - joints  of  relays P1 and P2  are open. 

Tryb

Tryb

P1   ON

P1P2   ON

Handwork

Handwork

Tryb

Tryb

P1   OFF

P1P2   OFF

Handwork

Handwork

 +23º
 +21º

O

K

O

K

O

K

O

K

O

K

O

K

O

K

O

K

O

K

O

K

O

K

O

K

O

K

O

K

T

ry

b

 

M

E

N

U

A

u

to

 M

o

d

e

T

ry

b

 

M

E

N

U

P

1

  

 O

N

 M

a

n

u

a

l

T

ry

b

 

M

E

N

U

P

1

  

 O

N

 S

a

v

e

d

T

ry

b

 

M

E

N

U

P

2

  

 O

N

 S

a

v

e

d

T

ry

b

 

M

E

N

U

P

1

P

2

 O

N

 S

a

v

e

d

T

ry

b

 

M

E

N

U

P

1

P

2

 O

F

F

 S

a

v

e

d

T

ry

b

 

M

E

N

U

P

2

  

 O

N

 M

a

n

u

a

l

T

ry

b

 

M

E

N

U

P

1

P

2

 O

N

 M

a

n

u

a

l

T

ry

b

 

M

E

N

U

P

1

P

2

 O

F

F

 M

a

n

u

a

l

T

ry

b

 

M

E

N

U

M

O

D

E

 

M

E

N

U

O

K

O

K

O

K

O

K

T

ry

b

 

M

E

N

U

M

a

n

u

a

l

 M

o

d

e

..

.

By buttons “UP” or “DOWN” choose program ( option to use are 
present under) and enter by button OK. Possible is return to main 
menu without save all changes by push button return.

Содержание CRT-06

Страница 1: ... panel for programming and monitoring 10 operation functions 2 independent temperature sensors two independent temperature values may be set 2 x 1Pcontacts applied to the temperature sensors 2 hysteresis set values one for each sensor AUTOMATIC mode operation with one selected function MANUAL mode permanent closing or opening of the contact without a temperature measurement Separate temperature dr...

Страница 2: ...et of output relays independent of reports from sensors 5 In automatic work will dispalied menu to select program one of tenth saved in device memory OK OK Menu Menu Info MENU System MENU Settings MENU Tryb MENU Mode MENU ATTENTION Choose handwork mode is signalize by sign R near sings which present position of relays P1 ON joint of relay P1 is close but joint of relay P2 is open P1P2 ON joints of...

Страница 3: ...nited temperature T2 and hysteresis threshold H2 T1 T1 H1 T1 H1 P1 P2 C1 Relays P1 and P2 works alternately P1 work in cooling mode closing joint when teperature fall under value T1 H1 and opening it when cross value T1 H1 Realy P2 work in heating mode closing joint when temperature fall under value T1 H1 and returnly opening it when cross value T1 H1 P1 P2 T1 T2 T1 H1 T2 H2 C1 T1 H1 T2 H2 C2 PROG...

Страница 4: ...ow mode two sensors Regulator works with two sensors C1 and C2 If temperature from two sensors will be in range which is definited by values T1 iandT2 then relay joints P1 and P2 will be closed C1 P1 P2 T1 T2 ATTENTION When will set value T2 T1 then regulator will be work correct PROG 10 Window mode two regulators Device works as two independent thermostats which works in window mode Sensor Czujni...

Страница 5: ...cision 1 C Ordered value of temperature T3 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 100 400 C with precision 1 C Ordered value of temperature T4 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 100 400 C with precision 1 C Value of hysteresis for temperature T1 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 1 100 C with precision 1 C Value of hysteresis for temperature ...

Страница 6: ...OK Menu Menu Menu Menu ATTENTION Work in safe mode is signalize by dispalied a sign In this cause pass to setting of regulator press button MENU is previuos by key correct a pin code Example of key PIN code 6 System Password This parameter is use to safe acces for all user to menu Password is a number from range 0 to 999 but save password to 0 unlock a menu Set password another than 0 cause pass t...

Страница 7: ...t NO Default sett YES Saved YES ATTENTION Return to default settings cause delete all earlier configurations with saved programs Rest of parameters of regulators are set with values Menu Info This Menu Info is use to display max and min values which were registered by temperature sensor OK OK Hi 54 Lo 23 Info MENU Code 01 Error Code 02 Error Error codes Wrong work of regulator is siganalize by bli...

Страница 8: ...ll cause break contolled device or menace for user In this cause producer is not responsible of arise accidents and could refuse given warranty for regulator in cause submit a claim A090706 sensor PT100 dimensions of sensor Ø4 h 85mm sensor isolation steel bush cable PC 3 0 34mm l 1 5m PROBE RT56 TECHNICAL DATA supply 230V AC current load 2 16A joint separated 1P range of regulation temperature 10...

Страница 9: ...01 0100 10 120 TCN4L 22R TX4H 14R TX4H 24R TX4H A4R TX4H B4R TX4L 14R TX4L A4R TX4L B4R TX4M 14R TX4M 24R TX4M A4R TX4M B4R QP99 CP 02 CP82 CP99 R38 LAOO R38 LARR 72 11304023 0150 0050 72 11304027 0150 0050 72 23304003 0150 0050 GGP 72 23904001 0300 0040 TM 72 34904001 0300 0040 TM TEM 73 A AT403 414 1000 AT403 614 1000 AT 503 1141 000 AT 503 1161 000 AT 503 6140 000 AT 603 1141 000 AT603 414 1000...

Отзывы: