background image

Example of change parameter value.

OK

OK

OK

OK

OK

OK

Tryb

 

MENU
Settings

 

MENU

Tryb

 

MENU
Temp.T1

 Set

Tryb

 

MENU
+  0°

 

Temp.T1

Tryb

 

MENU
+ 60°

 

Temp.T1

Tryb

 

MENU
+ 60°

 Saved

OK

OK

Tryb

 

MENU
Settings

 

MENU

OK

OK

Tryb

 

MENU
Temp.T1

 Settings

Tryb

 

MENU
Temp.T2

 Settings

Tryb

 

MENU
Temp.T3

 Settings

Tryb

 

MENU
Temp.T4

 Settings

Tryb

 

MENU
Hyst.T1

 Settings

Tryb

 

MENU
Hyst.T2

 Settings

 

MENU

 Settings

 

MENU

 Settings
 Delay T1

 

MENU

 Settings

Tryb

 

MENU
Cor.CT1

 Settings

Tryb

 

MENU
Cor.CT2

 Settings

Distinction

Delay T2

ATTENTION:

 Edition of setting is possible for parameter which 

are use ina executigram. When need to change parameter which 
isn’t use in program  then  option will not able.  

ATTENTION:

  Settings which were able to program, are present 

under ( numbers aren’t cross out):

Ordered value of temperature T1

Temperature  could  be  set  in  range:    -100÷400°C 
with precision 1°C.
ATTENTION!!:  Possible  is  quick  change  value  of 
ordered    temperature  T1  and  T2  without  pass  to 
menu-> settings. You need in standard work push 
button  OK.  It  cause  display  actual  value.  Next  by 
buttons “UP” or “DOWN” set new value and enter by 
OK. If need edit next temperature push button OK. 
Push a button return cause out from edition mode 
without save all changes.  

1

2

3

4

5

6

7

8

9

10

Tryb

 

MENU
Temp.T1

 Settings

Ordered value of temperature T2.
Te m p e r a t u r e   c o u l d   b e   s e t   i n   r a n g e  
-100÷400°C  with precision 1°C.

Ordered value of temperature T3.
Te m p e r a t u r e   c o u l d   b e   s e t   i n   r a n g e  
-100÷400°C  with precision 1°C.

Ordered value of temperature  T4.
Te m p e r a t u r e   c o u l d   b e   s e t   i n   r a n g e  
-100÷400°C  with precision 1°C.

Value of hysteresis for temperature T1. 
Te m p e r a t u r e   c o u l d   b e   s e t   i n   r a n g e  
1÷100°C  with precision 1°C.

Value of hysteresis for temperature T2. 
Te m p e r a t u r e   c o u l d   b e   s e t   i n   r a n g e  
1÷100°C  with precision 1°C.

Ordered  distiction  of  temeratures  which  is  use  as 
parameter prog 7.
Distiction  of  temperaturs  could  be  set  in  range 
1÷500°C  with precision 1°C.

1

1

1

1

1

1

2

2

2

2

2

2

3

3

3

3

3

3

4

4

4

4

4

4

5

5

5

5

5

5

6

6

6

6

6

6

7

7

7

7

7

7

8

8

8

8

8

8

9

9

9

9

9

9

10

10

10

10

10

10

Tryb

 

MENU
Temp.T2

 Settings

Tryb

 

MENU
Temp.T3

 Settings

Tryb

 

MENU
Temp.T4

 Settings

Tryb

 

MENU
Hyst.T1

 Settings

Tryb

 

MENU
Hyst.T2

 Settings

 

MENU

 Settings

Distiction

Minimal time  to hold a one  position  (ON or OFF) of 
retay output
Parameter DelayT2 is dependent from sensor  C2.
Example of work for prog 1 with   delay . Delay was 
present in earlier point.

Correction of sensor reports C1. 
Sensor reprts could be corrected   by   ±20°C with 
precision  1°C.

Minimal time   to execute one cycle of program (ON 
or OFF)
Parameter DelayT1 is dependent from sensor  C1.
Example  of  work  for  prog  1  with    delay  .  Delay  is 
present on under picture..

1

1

1

2

2

2

3

3

3

4

4

4

5

5

5

6

6

6

7

7

7

8

8

8

9

9

9

10

10

10

 

MENU

 Settings

 

MENU

 Settings

Tryb

 

MENU
Cor.CT1

 Settings

P1

P2

C1

T

1

T - H

1

T + H

1

     Delay

     Delay

    Delay

Delay T1

Delay T2

Содержание CRT-06

Страница 1: ... panel for programming and monitoring 10 operation functions 2 independent temperature sensors two independent temperature values may be set 2 x 1Pcontacts applied to the temperature sensors 2 hysteresis set values one for each sensor AUTOMATIC mode operation with one selected function MANUAL mode permanent closing or opening of the contact without a temperature measurement Separate temperature dr...

Страница 2: ...et of output relays independent of reports from sensors 5 In automatic work will dispalied menu to select program one of tenth saved in device memory OK OK Menu Menu Info MENU System MENU Settings MENU Tryb MENU Mode MENU ATTENTION Choose handwork mode is signalize by sign R near sings which present position of relays P1 ON joint of relay P1 is close but joint of relay P2 is open P1P2 ON joints of...

Страница 3: ...nited temperature T2 and hysteresis threshold H2 T1 T1 H1 T1 H1 P1 P2 C1 Relays P1 and P2 works alternately P1 work in cooling mode closing joint when teperature fall under value T1 H1 and opening it when cross value T1 H1 Realy P2 work in heating mode closing joint when temperature fall under value T1 H1 and returnly opening it when cross value T1 H1 P1 P2 T1 T2 T1 H1 T2 H2 C1 T1 H1 T2 H2 C2 PROG...

Страница 4: ...ow mode two sensors Regulator works with two sensors C1 and C2 If temperature from two sensors will be in range which is definited by values T1 iandT2 then relay joints P1 and P2 will be closed C1 P1 P2 T1 T2 ATTENTION When will set value T2 T1 then regulator will be work correct PROG 10 Window mode two regulators Device works as two independent thermostats which works in window mode Sensor Czujni...

Страница 5: ...cision 1 C Ordered value of temperature T3 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 100 400 C with precision 1 C Ordered value of temperature T4 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 100 400 C with precision 1 C Value of hysteresis for temperature T1 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 1 100 C with precision 1 C Value of hysteresis for temperature ...

Страница 6: ...OK Menu Menu Menu Menu ATTENTION Work in safe mode is signalize by dispalied a sign In this cause pass to setting of regulator press button MENU is previuos by key correct a pin code Example of key PIN code 6 System Password This parameter is use to safe acces for all user to menu Password is a number from range 0 to 999 but save password to 0 unlock a menu Set password another than 0 cause pass t...

Страница 7: ...t NO Default sett YES Saved YES ATTENTION Return to default settings cause delete all earlier configurations with saved programs Rest of parameters of regulators are set with values Menu Info This Menu Info is use to display max and min values which were registered by temperature sensor OK OK Hi 54 Lo 23 Info MENU Code 01 Error Code 02 Error Error codes Wrong work of regulator is siganalize by bli...

Страница 8: ...ll cause break contolled device or menace for user In this cause producer is not responsible of arise accidents and could refuse given warranty for regulator in cause submit a claim A090706 sensor PT100 dimensions of sensor Ø4 h 85mm sensor isolation steel bush cable PC 3 0 34mm l 1 5m PROBE RT56 TECHNICAL DATA supply 230V AC current load 2 16A joint separated 1P range of regulation temperature 10...

Страница 9: ...01 0100 10 120 TCN4L 22R TX4H 14R TX4H 24R TX4H A4R TX4H B4R TX4L 14R TX4L A4R TX4L B4R TX4M 14R TX4M 24R TX4M A4R TX4M B4R QP99 CP 02 CP82 CP99 R38 LAOO R38 LARR 72 11304023 0150 0050 72 11304027 0150 0050 72 23304003 0150 0050 GGP 72 23904001 0300 0040 TM 72 34904001 0300 0040 TM TEM 73 A AT403 414 1000 AT403 614 1000 AT 503 1141 000 AT 503 1161 000 AT 503 6140 000 AT 603 1141 000 AT603 414 1000...

Отзывы: