Two post hydraulic lift QJY3.0-E
14
6.3.2 Greasing points
l
Slide tracks
The slide tracks inside the columns should be greased every six months (or more
frequently in case of noise generation).
Slightly greases the slide tracks over their whole length using a brush.
l
Arm extensions
1. Every six months check the support arm extensions for smooth operation.
2. Grease as required.
6.3.3 Operational and wear checks
l
Rubber Pads of Disk Adapters
1. Weekly check the rubber pads for wear.
2. Replace them as required.
l
Arm Restraints
Weekly check the arm restraints for secure engagement.