Examples of technical alarms are sum alarms from the lift controller or sensors from the lift car
doors and more.
Note: If the alarm input is connected to the lift controller or other external devices the connection
must be separated using a relay connection.
Setting of alarm input 1
By default the alarm input 1 is auto-detecting. When the ECII™ Flex is powered up or when
setting default settings the unit will automatically set the alarm input 1 to the same function as
the installed alarm button. The auto-detect setting can be overridden by programming N/O or
N/C forcing the ECII™ Flex to use this setting.
If the ECII™ Flex version with integrated alarm button is used it is already connected to the lift
phone alarm input. If the alarm button has normally open function the ECII™ Flex must be
programmed accordingly:
Set normally open alarm button:
From keypad:
From phone:
020 #
Reset to normally closed alarm button:
From keypad:
From phone:
# 020 #
Note: If alarm input 1 is filtered there is a 30 second override; meaning if the alarm button is
pushed more than 30 seconds an emergency alarm will be sent even though the filter signal is
active. This can also be used for accessing programming mode when using filtering.
Setting of alarm input 2
This input is of open/closed character and can be used for a filtering signal, technical alarm or
a normal emergency alarm. It is configured as follows:
X is either
0 = Normally Open
1 = Normally Closed
Y is either
0 = Emergency alarm
1 = Technical alarm
2 = Filtering signal
3 = Use external microphone on input 2 trigger
Alarm input 2 is deactivated by default, function is activated by:
From keypad:
< X >
< Y >
From phone:
021
< X >
< Y > #
Function is deactivated with:
From keypad:
From phone:
# 021 #
Example:
Program N/O and emergency alarm:
Program N/C and emergency alarm:
Program N/O and technical alarm:
Example: When alarm input 2 is configured as a filtering signal it will affect the functionality of