6.2 ELECTRICAL SUPPLY AND CONNECTION
6.2.1
Remove rear access panel to access the inlet terminal (see 6.2.2)
6.2.2 Cable entry at unit rear. A suitable rated isolating switch with contact
separation of at least 3mm in all poles must be installed and wiring executed
in accordance with relevant regulations.
This appliance is also provided with a
terminal for connection of an external
equipotential conductor. This terminal is in
effective electrical contact with all fixed
exposed metal parts of the appliance, and
shall allow the connection of conductor
having a nominal cross-section area of up
to 10mm². It is located at the rear of the unit
and identified by the following label and
must only be used for bonding purposes.
The electrical connections color code is shown in the table below.
PHASE I
PHASE II
PHASE III
NEUTRAL
EARTH
Brown
Black
Grey
Blue
Green/Yellow
MAINS INPUT CONNECTION CABLE IS NOT SUPPLIED; SUITABLE
CABLE WILL CONFORM TO CODE DESIGNATION IEC 60245-57.