When connecting to a single phase supply, the three line terminals must be connected 
together using the wire links provided. It is important that the links and incoming supply cable 
are connected exactly as shown in the following diagram. 
 
 
 
 
 
 
 
 
 
 

1.4 ELECTRICAL RATING 

The electrical loadings are as stated on the appliance data plate. 
 

1.5 FAN UNIT 

This is a unit specially developed for use in forced convection ovens. It has two fans directly 
mounted on the motor shaft. The larger fan is inside the oven, the purpose being to circulate 
air around the cooking space whilst the smaller externally mounted fan serves to cool the 
motor. 
 

1.6 INSTRUCTION TO USER 

Hand the USER'S INSTRUCTIONS to the user or purchaser and ensure that the instructions 
for the correct use and cleaning are properly understood. 
The location of the electrical supply switch should be made known to the user for use in an 
emergency or during cleaning. 
 

SECTION 2 - ASSEMBLY and COMMISSIONING 
 

Warning 
 

Due to the appliance weight (see Section 1.1), it is recommended that when lifted manually, 
that it be supported by 4 people (one at each corner). 
 

Important 

Care must be taken when lifting heavy loads and ensure that correct lifting techniques are 
employed. For reference see the HSE publication, Manual Handling of Loads Regulations. 
 

2.1 ASSEMBLY 
2.1.1  Oven without Stand 

a) Unpack unit and remove all loose components from oven compartment. 
b) Manoeuvre oven to required position and level using the adjustable feet. Also, refer to 
Section 2.1.3 if applicable.  
c)  Connect electricity supply.  
d)  Insert the shelves within the oven. 

Note 

Feet can be secured to floor using holes provided. 

2.1.2 Oven with Stand 

a) Unpack unit and stand. Remove all loose components from oven compartment. 
b)  Ensure the leg securing bolts are turned fully back. 
c) Lift oven on to stand. If a stand is fitted with castors, these should be locked. 
d)  Tighten leg stand securing bolts. 
e)  Manoeuvre unit into position. 
f)   For stand on castors, fit securing chain to prevent straining the electrical cable. 

Содержание E7204

Страница 1: ...iance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR...

Страница 2: ...Cleaning adjustment of pilots Correction of gas pressure to appliance Renewing of electric cable ends Replacement of fuses Corrosion caused by use of chemical cleaners Electrical Safety and Advice Reg...

Страница 3: ...ended that it be positioned at the RH end to provide unrestricted access for servicing of controls etc If the unit is to be installed in a suite either centrally or adjacent to a wall with a boxed in...

Страница 4: ...cleaning SECTION 2 ASSEMBLY and COMMISSIONING Warning Due to the appliance weight see Section 1 1 it is recommended that when lifted manually that it be supported by 4 people one at each corner Impor...

Страница 5: ...n controlled by a PLC programmable logic controller The fan timings are For heat up mode door closed Operation Duration seconds OFF start up 12 then repeat loop Anti clockwise 120 OFF 12 Clockwise 120...

Страница 6: ...oven temperature settles to 80o C 5o C SECTION 3 SERVICING Warning BEFORE CARRYING OUT ANY MAINTENANCE ON THIS APPLIANCE ENSURE THE UNIT ELECTRICITY SUPPLY IS ISOLATED Controls are removed as follows...

Страница 7: ...e in reverse order 3 11 BUZZER INPUT MAINS FILTER and START RUN RELAY a Remove side panel as detailed in Section 3 2 b Disconnect electrical leads c Remove fixing which secures component to inner cont...

Страница 8: ...ng screws f Replace in reverse order Take care to ensure that safety thermostat bracket is correctly positioned Note Oven baffle is not symmetrical fixings have been offset to ensure correct relocatio...

Страница 9: ...kage adjustment section door linkage alignment section and Figures 2 and 3 3 23 DOOR LINKAGE ADJUSTMENT and TENSIONING Due to operational stretching of components or removal for maintenance occasions...

Страница 10: ...panel front sides b Unhook spring and remove nut and split pins from top of toggle plate pins c Replace new component s Take care to re assemble in correct order d Replace top panel 3 26 DOOR WINDOW E...

Страница 11: ...00360 Door Seal E7204 531930526 Door Seal E7208 532930043 Door Seal E7211 531940099 Neon Red 730962010 Neon Amber 730962040 Cool Heat Switch 732920047 Cook Hold Switch 732920051 Fan Switch 732910481 T...

Страница 12: ......

Страница 13: ......

Отзывы: