Repeat commission visits. 
Replacement of any parts where damage has been caused by misuse. 
Engineer waiting time will be chargeable. 
Routine maintenance and cleaning. 
Gas conversions i.e. Natural to Propane gas. 
Descaling of water products and cleaning of water sensors where softeners/conditioners are not 
fitted, or are fitted and not maintained. 
Blocked drains. 
Independent steam generation systems. 
Gas, water and electrical supply external to unit. 
Light bulbs. 
Re-installing vacuum in kettle jackets. 
Replacement of grill burner ceramics when damage has been clearly caused by misuse. 
Where an engineer finds no fault with a product that has been reported faulty. 
Re-setting or adjustment of thermostats when unit is operating to specification. 
Cleaning and unblocking of fryer filter systems due to customer misuse. 
Lubrication and adjustment of door catches. 
Cleaning and Maintenance: 

Cleaning of burner jets  
Poor combustion caused by lack of cleaning 
Lubrication of moving parts       
Lubrication of gas cocks       
Cleaning/adjustment of pilots       
Correction of gas pressure to appliance       
Renewing of electric cable ends       
Replacement of fuses       
Corrosion caused by use of chemical cleaners. 

 
 

Electrical Safety and Advice Regarding Supplementary Electrical Protection 

Commercial kitchens and foodservice areas are environments where electrical appliances may be located 
close to liquids, or operate in and around damp conditions, or where restricted movement for installation 
and service is evident. 

The installation and periodic inspection of the appliance should only be undertaken by a qualified, skilled 
and competent electrician; and connected to the correct power supply suitable for load as stipulated by the 
appliance data label. 

The electrical installation and connections should meet the necessary requirements to local electrical 
wiring regulations and electrical safety guidelines. 

We recommend:- 

 

Supplementary electrical protection with use of a residual current device (RCD). 

 

 

 

Fixed wiring appliances incorporate a locally situated switch disconnector to connect to, which is 
easily accessible for switching off and safe isolation purposes. The switch disconnector must meet 
the specification requirements of IEC 60947.

Содержание E7204

Страница 1: ...iance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR...

Страница 2: ...Cleaning adjustment of pilots Correction of gas pressure to appliance Renewing of electric cable ends Replacement of fuses Corrosion caused by use of chemical cleaners Electrical Safety and Advice Reg...

Страница 3: ...ended that it be positioned at the RH end to provide unrestricted access for servicing of controls etc If the unit is to be installed in a suite either centrally or adjacent to a wall with a boxed in...

Страница 4: ...cleaning SECTION 2 ASSEMBLY and COMMISSIONING Warning Due to the appliance weight see Section 1 1 it is recommended that when lifted manually that it be supported by 4 people one at each corner Impor...

Страница 5: ...n controlled by a PLC programmable logic controller The fan timings are For heat up mode door closed Operation Duration seconds OFF start up 12 then repeat loop Anti clockwise 120 OFF 12 Clockwise 120...

Страница 6: ...oven temperature settles to 80o C 5o C SECTION 3 SERVICING Warning BEFORE CARRYING OUT ANY MAINTENANCE ON THIS APPLIANCE ENSURE THE UNIT ELECTRICITY SUPPLY IS ISOLATED Controls are removed as follows...

Страница 7: ...e in reverse order 3 11 BUZZER INPUT MAINS FILTER and START RUN RELAY a Remove side panel as detailed in Section 3 2 b Disconnect electrical leads c Remove fixing which secures component to inner cont...

Страница 8: ...ng screws f Replace in reverse order Take care to ensure that safety thermostat bracket is correctly positioned Note Oven baffle is not symmetrical fixings have been offset to ensure correct relocatio...

Страница 9: ...kage adjustment section door linkage alignment section and Figures 2 and 3 3 23 DOOR LINKAGE ADJUSTMENT and TENSIONING Due to operational stretching of components or removal for maintenance occasions...

Страница 10: ...panel front sides b Unhook spring and remove nut and split pins from top of toggle plate pins c Replace new component s Take care to re assemble in correct order d Replace top panel 3 26 DOOR WINDOW E...

Страница 11: ...00360 Door Seal E7204 531930526 Door Seal E7208 532930043 Door Seal E7211 531940099 Neon Red 730962010 Neon Amber 730962040 Cool Heat Switch 732920047 Cook Hold Switch 732920051 Fan Switch 732910481 T...

Страница 12: ......

Страница 13: ......

Отзывы: