SECTION 1
– INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE
MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER
1.1 MODEL NUMBER, NETT WEIGHTS and DIMENSIONS
MODEL
WIDTH mm
DEPTH mm
HEIGHT mm
WEIGHT kg
E7204
860
1015
1470
170
E7208
1000
1070
1525
220
E7208/2
1000
1070
1910
420
E7211
1000
1070
1525
270
E7211 Trolley
820
740
910
32
E7211 Rack
680
560
830
37
1.2 SITING
The oven must be situated on a reasonably level surface. The unit feet are adjustable to
facilitate levelling however, the adjustment range is limited.
Installation must be executed in accordance with local and/or national regulations listed on
the cover of this manual. A competent installer must be employed.
1.2.1 Installing Clearances
A clearance of at least 150mm must be allowed from any combustible wall. Clearance must
also be allowed at the rear from any non-combustible wall to let cooling air into the rear fan.
If practicable, it is recommended that a clearance of at least 400mm be allowed from any
side wall. This will provide access for adjustment of the rear levelling bolts and to effect
removal of the RH side panel to facilitate servicing. If the unit is being installed as part of a
suite, it is further recommended that it be positioned at the RH end to provide unrestricted
access for servicing of controls etc.
If the unit is to be installed in a suite, either centrally or adjacent to a wall with a 'boxed in'
void at the rear, it is important that the void be adequately ventilated. This will ensure a
supply of air to the motor cooling fan at the rear of the oven.
1.3 ELECTRICAL SUPPLY
This unit is suitable for AC supplies only. The standard terminal arrangement is for 3 phase,
4 wire connection, but by linking the 3 line terminals, the unit can be connected to a single
phase supply.
The cable entry is at the bottom RH rear of the unit via a 32mm dia conduit. Access to the
terminals is gained by removing the RH side panel.
A suitably rated isolating switch with a minimum 3mm contact separation in all poles must be
installed and the wiring executed in accordance with the relevant regulations listed on the
front cover of this manual.
Warning
The appliance must be earthed. (An earth terminal is provided).
The appliance is also provided with a terminal for the connection of an
external equipotential conductor. This terminal is in effective electrical contact
with all fixed exposed metal parts of the appliance, and shall allow the
connection of a conductor having a nominal cross-sectional area of up to 10
mm². It is located on the rear panel and is identified by the following label and
must only be used for bonding purposes.