WARNING SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity before servicing. Check appliance is safe when you have finished.
electrical supply can be made with either a plug and socket
or be permanently wired via a double - pole switch.
The appliance is supplied with a 250v high
temperature PVC (85°C) 3 core cable, 0.75mm
2
,
2m long. If a replacement cable is fi tted it must be
to this specifi cation. The cooker may possibly be
supplied with either a moulded or rewirable plug
fi tted. Should the plug (where supplied) not fi t the
socket in your home, it should be removed and
replaced with a suitable plug.
Note: If a moulded plug is fi tted which is not
suitable, it must be cut off and disposed of
properly. To avoid the risk of electrocution, the
moulded plug must not be left where children
might fi nd it and plug it into a supply socket. It
must not be used for any other appliance.
IMPORTANT
The wires in the mains lead are coloured in accordance with
the following code:-
GREEN AND YELLOW ............. EARTH
BLUE ............................................. NEUTRAL
BROWN ....................................... ACTIVE
The wires should be connected into the terminal of your
plug as follows:-
EARTH: ........ to the terminal marked E, or coloured
GREEN or GREEN / YELLOW.
NEUTRAL: ... to the terminal marked N, or coloured
BLACK or BLUE.
ACTIVE: ....... to the terminal marked A, or coloured RED
or BROWN.
When wiring the plug ensure that all strands of wire are
retained in each terminal.
The fl exible mains lead, plug and socket must not be
directly exposed to fl ue products or be in contact with hot
surfaces. The lead must not be trapped or pulled taut when
the appliance is pushed into position.
Plug in the appliance. Turn on the electricity supply.
If there is an electrical fault carry out the following checks:-.
Electrical checks
EARTH CONTINUITY CHECK
The cooker must be disconnected from the power supply.
Set your meter to (ohm) on the X1 scale and adjust to
zero if necessary.
Test the leads from any of the cooker’s earth points (e.g.
inside electric box cover) - to the earth pin on the cooker’s
plug - resistance should be less than l (ohm). If it is not,
check all the earth wires for continuity. Check that all
contacts are clean and tight. Re-check. If the resistance is
still greater than l (ohm) there may be a problem, consult
a qualifi ed electrical engineer.
POLARITY CHECK
The cooker must be connected to the power supply. Your
meter should be set on 300V ac scale.
Test at the cooker terminal block:
1. Test leads from A to N. Your meter should read
approximately 240V ac.
2. Test leads from A to E. Your meter should read
approximately 240V ac.
3. Test leads from N to E. Your meter should read approx.
0-15V ac.
If the readings are diff erent from these values there is
an electrical fault. Rectify any fault and repeat the test.
If necessary repeat the test at the supply system socket/
spur - if the fault also occurs at this stage then there is a
house system fault that requires attention by the Electrical
Authority.
The customer should be warned NOT to use the appliance
until this examination has been carried out.
Fitting the plinth
Loosen the 3 screws along the front bottom edge of the
cooker. Hook the central keyhole over the central screw.
Twist and fi t each end keyhole over their respective screws.
Tighten the fi xing screws.
Oven Light
Press the oven light switch and check that the light is
working.
NB The oven light bulb is not included in the
guarantee
Hotplate check
Check each burner in turn. Press ignition switch on control
panel. Push in tap and turn to the large fl ame symbol ( ).
Grill
Open the grill compartment door. Press ignition switch on
control panel. Press in the grill knob, turn to the large fl ame
symbol ( ).
Fitting the oven burner trim (supplied
with some models only)
The loose oven burner trim hooks onto the front of the
oven burner bracket.