Example: OUTP:PROT:CURR 10
Query syntax: OUTPut:PROTect:CURRent?
Returned parameter: <NRf>[Unit=A]
OUTPut:PROTect:POWer
Set power supply overpower protection threshold.
Command syntax: OUTPut:PROTect:POWer <NRf>
Parameter: MIN
~
MAX
Unit: W (Watt)
Example: OUTP:PROT:POW 1000.0
Query syntax: OUTPut:PROTect:POWer?
Returned parameter: <NRf>[Unit=W]
OUTPut:PROTect:CLEar
Clear the protection state or fault of the power supply.
Command syntax: OUTPut:PROTect:CLEar
Example: OUTP:PROT:CLE
Parameter: None
Query syntax: None
3.4. SOURce command
SOURce:VOLTage[:LEVel]
Set static output voltage.
Command syntax: SOURce:VOLTage[:LEVel] <NRf>
Parameter: MIN
~
MAX
Unit: V (Volt)
Example: SOUR:VOLT 25.0
Query syntax: SOURce:VOLTage[:LEVel]?
Returned parameter: <NRf>[Unit=V]
SOURce:VOLTage:LIMit:HIGH
Set static output voltage upper limit, in order to protect the DUT.