FTG Series Programming Manual
_________________________________________________________________
21
Command syntax: SOURce:VOLTage:LIMit:HIGH <NRf>
Parameter: MIN
~
MAX
Unit: V (Volt)
Example: SOUR:VOLT:LIM:HIGH 80.0
Query syntax: SOURce:VOLTage:LIMit:HIGH?
Returned parameter: <NRf>[Unit=V]
SOURce:VOLTage:LIMit:LOW
Set static output voltage lower limit, in order to protect the DUT.
Command syntax: SOURce:VOLTage:LIMit:LOW <NRf>
Parameter: MIN
~
MAX
Unit: V (Volt)
Example: SOUR:VOLT:LIM:LOW 10.0
Query syntax: SOURce:VOLTage:LIMit:LOW?
Returned parameter: <NRf>[Unit=V]
SOURce:CURRent[:LEVel]
Set static output current.
Command syntax: SOURce:CURRent[:LEVel] <NRf>
Parameter: MIN
~
MAX
Unit: A (Ampere)
Example: SOUR:CURR 5.0
Query syntax: SOURce:CURRent[:LEVel]?
Returned parameter: <NRf>[Unit=A]
SOURce:CURRent:LIMit:HIGH
Set static output current upper limit, to protect the DUT.
Command syntax: SOURce:CURRent:LIMit:HIGH <NRf>
Parameter: MIN
~
MAX
Unit: A (Ampere)
Example: SOUR:CURR:LIM:HIGH 30.0
Query syntax: SOURce:CURRent:LIMit:HIGH?
Returned parameter: <NRf>[Unit=A]