24
SEQuence:EDIT:STEP
Set the step number for the present step being edited.
Command syntax: SEQuence:EDIT:STEP <NR1>
Parameter: 1
~
100
Example: SEQ:EDIT:STEP 1
Query syntax: SEQuence:EDIT:STEP?
Returned parameter: <NR1>
SEQuence:EDIT:VOLTage
Set output voltage for present step in sequence file.
Command syntax: SEQuence:EDIT:VOLTage <NRf>
Parameter: MIN
~
MAX
Unit: V (Volt)
Example: SEQ:EDIT:VOLT 12.0
Query syntax: SEQuence:EDIT:VOLTage?
Returned parameter: <NRf>[Unit=V]
SEQuence:EDIT:CURRent
Set output current for step in sequence file.
Command syntax: SEQuence:EDIT:CURRent <NRf>
Parameter: MIN
~
MAX
Unit: A (Ampere)
Example: SEQ:EDIT:CURR 5.0
Query syntax: SEQuence:EDIT:CURRent?
Returned parameter: <NRf>[Unit=A]
SEQuence:EDIT:DELay
Set delay time of the present step in sequence file.
Command syntax: SEQuence:EDIT:DELay <NRf>
Parameter: MIN
~
MAX
Unit: s (Second)
Example: SEQ:EDIT:DEL 1.0
Query syntax: SEQuence:EDIT:DELay?