30iE - v1111 - Installation/Operation - (14/48)
PAR20 bit 4 = 1 (the outputs are deactivated when reaching the home position)
2.5.1.1 Programming the levels
The levels are set by installation parameters PAR40 (for output O1) through PAR45
(for output O6); to access them directly:
The dro displays must be on, reading mode and press the following keys:
The X axis display shows the word "
COdE
".
060496
The displays of the DRO show
PAR00
.
Once in regular display mode
, parameters
PAR40 through PAR45
(output levels)
may also be recalled by pressing this keystroke sequence, so the work mode may be
changed without having to go through all the previous steps.
2.5.1.2 Deactivate the outputs:
Desactivas the digital outputs. The screen will blink the text “
OUTS OFF
”. See
parameter 65 to activate this function.
P1 (Home)
P2
P3
P4
P5
P6 (End)
O1
O2
O3
O4
O5
O6
CODE: 060496