Description of operation
t e c h n i c a l
17
3.6.2.- Seguridades criterios
SAFETY
MECHANISMS
FAULT CONDITION
WASHER ACTION
RESET
(End of safety)
FILLING
F01
EV ON 8 min. and PN
OFF (empty)
(except in reliability
programme)
It remains on pause with
door lock ON
Any of these conditions
resets the safety:
1. – Power is lost (supply
or ON/OFF switch).
2.- Change of programme
selector position.
UNBALANCED
F03
Detects imbalance in
18 attempts (15 min)
of low imbalance level
(see spin table)
It performs 2 attempts
with the high imbalance
level, limiting the speed
to C1.
Even if it spins at this
speed, it will indicate the
fault (see spin table).
NTC
F05
NTC in short circuit or
open circuit
It performs the selected
programme but without
heating
NO HEATING
F06
B < 5º C / 15 min.
(excepto en programa
fiabilidad)
EMPTYING
F02
EB ON 6 min. and PN
ON (full)
STOP
(End of programme)
OVERFULL
F07
Drainage pump cuts
out or loses electricity
supply
F07
Electronic operated
valve cuts out
DOOR LOCK
F04
Door lock ON and
also detects failure
of both control triacs
of the door lock (both
open)
PROGRAMME
SELECTOR
F08
Selector in short
circuit or open circuit
Performs DELICATE cold
programme (only in User
Mode)
MOTOR
F09
Tachogenerator
motor lock fault (three
consecutive attempts)
STOP
End of programme
Door lock always closed
INVERSION
WITH MOTOR
STOPPED
F10
Does not invert the
direction until the
motor stops (Max.
time (1 min.)
The fault indicator disap-
pears, as in previous
cases but the door lock is
kept closed.
To unlock it, keep it OFF.
B= pending increase in temperature when heating