Description of operation
t e c h n i c a l
13
3.5.- Fagor circuit confi guration:
3.1.3.- Fagor circuit configuration:
If the circuit is not configured, it will go into
To change the configuration, follow these steps:
1.- Turn the machine off
2.- Press the start / pause button and keep it pressed (until step 5)
3.- Press the button for 1 second until the LCD screen lights up
4.- Press the spin button and wait 2 seconds until the letter is displayed
on the LCD screen
5.- Release all keys simultaneously
6.- The door lock will be locked
7.- Press the spin button and the configuration digits are displayed
(the last digit of the LCD will flash).
8.- Pressing the Time Delay button changes the parameter to be adjusted,
starting with the KG digit and following the sequence:
KG – RPM – RECIRCULATION – COLD WATER – DOOR OPENING– KG - ….….
Pressing the SPIN button changes the value of the parameter; the possible values
are limited to the circuit’s hardware reference and the selected KGs. If the KGs
are changed after having selected the RPM, and the previous RPM value is not
permitted for the newly selected KGs, the RPM will re-adjust to the value closest
for the newly selected KGs.
1200
RPM
RECIRCULATION PUMP
YES 00 / NO 0
COLD WATER
YES 0 / NO 8
DOOR OPENING
YES 8 / NO 0
KG
6
Select
Select
status as soon as it is plugged in
(go to step no. 7). If the circuit is configured it enters the current configuration.