Description of operation
t e c h n i c a l
11
NTC Temperature / Resistance values
Temperature(ºC)
<30
30
35
40
57
60
80
90
Resistance (K
Ω
)
>40
39
31
26
13
11
5
4
Component
Function
Features
Drainage pump
Drains the water from
inside the drum
Voltage: 220 v / 50 Hz
Drainage rate: 16 litres/
minute
Maximum drainage
height: 1 metre
Winding resistance: 163.4
Ω
Power 30 Watt.
Quadruple valve
The pressure switch
is activated in the
following conditions:
When the level reaches
12 litres, the wash
level. (11-12)
- When the level
exceeds 33 litres
(overflow), the
drainage pump is
activated (safety).
(11-16)
- The rinse level is
performed according
to the time of the
microprocessor of the
electronic card.
Level 1
102 / 72 ± 3
Overflow safety
310 ± 10
12 Water outlet
14 Heating
16 Overflow
11 Common
11
12
14
16
Presostato
Water input during pre-
wash, wash and softener.
Voltage 220 V/50 Hz
Electrically operated valve
fl
ow for pre-wash, wash
and softener is 7 litres per
minute.
Electrically operated valve
fl
ow for drying is 0.35
litres per minute.
Value: 3,750
Ω