·56·
Hard ware confi gura tion
CNC 8065
4.
(R
EF
: 1404)
CENTRAL UNI
T I
CU.
4.5
Power connection.
Voltage supply for the central unit.
The central unit is powered by an external DC power supply; use a 24 V DC ±10% and 3.5
A. power supply.
It is also possible to connect an external battery that ensures the proper operation of the unit
under AC power outages. See chapter
Over-current at the power supply.
An over-current activates the safety device inside the power supply turns on the external red
LED. The power supply will not be operative while the LED is on. There are two ways to
reactivate the power supply after an over-current.
• Unplug the power supply from mains and wait for about 30 seconds until the red light turns
off.
• Unplug the power supply and press the ·LATCH· button. The red LED will turn off
indicating that the power supply is ready.
If after reactivating the power supply, the LED turns back on, call the Technical Service
Department.
Consult the electrical characteristics of the central unit before connecting the power supply. See