·36·
Hard ware confi gura tion
CNC 8065
4.
(R
EF
: 1404)
CENTRAL UNI
T I
CU.
4.1
Technical characteristics.
Electrical characteristics.
• Universal DC power supply.
Use a 24 Vdc ±10% 3.5 A power supply. Current peak of 90 A on power-up.
• Protection against over-voltage and reverse voltage.
The central unit has a fuse that may be accessed from the outside to protect against over-
voltage (greater than 36 V DC or 25 V AC). The central unit is also protected against
reverse connection of the power supply, preventing it from starting up.
• Protection against over-current.
An over-current activates the safety device inside the power supply. The central unit has
an LED that turns on when this device is active.
To reactivate the power supply after an over-current, just press the button for it or turn
it off for 30 seconds. If the led comes back on, call the Technical Service.
• Power outages.
Meets the EN 61000-4-11 regulation. The central unit is capable of withstanding micro-
outages of up to 10 milliseconds.
Vibrations.
• Sweep sine trial with a frequency step of 1 octave/minute (±10%) and 10 sweeps long.
Packaging and resistance to falls.
• Packaging: Meets the EN 60068-2-32 regulation.
• Free fall packaged according to Fagor regulations (1 meter):
9 Hz
≥
f
≥
5 Hz
Constant movement with an amplitude of 3 mm.
200 Hz
≥
f
≥
9 Hz
Constant 1g acceleration.