·48·
Hard ware confi gura tion
CNC 8065
4.
(R
EF
: 1404)
CENTRAL UNI
T I
CU.
CAN bus. ·CAN· connector.
5-pin male Phoenix minicombicon contact (3.5 mm pitch).
For further information on how to configure the connection of the elements to the CAN bus,
refer to chapter
"10 Bus CAN (CANfagor/CANopen protocols)."
of this manual.
CAN bus. ·ST· selector.
Line terminating resistor. The ·LT· switch identifies which are the elements that occupy the
ends of the CAN bus; i.e. the first and last physical element in the connection.
The switch position of the terminating elements must be "1" and that of the rest of the
elements "0".
CAN bus. ·ERROR· LED.
Red LED. Its meaning depends on the blinking speed.
CAN bus. Led ·RUN·.
The LED is green. Its meaning depends on the blinking speed.
Bus used to communicate with Fagor drives. Sercos Bus.
·IN· & ·OUT· connectors Honeywell emitter and receiver.
For further information on how to configure the connection of the elements to the Sercos bus,
refer to chapter
of this manual.
Type of blinking.
Meaning.
LED off.
The module works properly.
Blinking fast.
Module configuration stage.
Single blinking.
Warning. Poor transmission.
Double blinking.
There is no communication with the cpu.
LED on.
Error. Too many errors.
Type of blinking.
Meaning.
LED on.
The module works properly.
Single blinking.
Module stopped.
Blinking fast.
Module configuration stage.
Continuous blinking.
Start-up stage or error.
1
2
3
4
5
ISO GND
CAN L
SHIELD
CAN H
SHIELD
Pin.
Signal.
Function.
1
ISO GND
Ground / 0 V.
2
CAN L
(LOW) bus signal.
3
SHIELD
CAN shield.
4
CAN H
(HIGH) bus signal.
5
SHIELD
CAN shield.
Signal.
Function.
IN
Sercos signal receiver.
OUT
Sercos signal emitter.
SERCOS
IN
OUT
Содержание CNC 8065
Страница 1: ...Ref 1404 8065 CNC Hardware configuration...
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 16: ......
Страница 20: ......
Страница 22: ......
Страница 110: ...110 Hardware configuration CNC 8065 REF 1404...