Remote modules.
CNC 8060
CNC 8065
5.
RIOW REMOTE MODULES.
(CANOPEN
PROTOCOL).
RIOW-CANOPEN-STAND
mod
ule.
Lead
ing
(first)
modu
le.
·90·
(R
EF
: 1906)
5.5.4
Meaning of the LED's.
While staring the module up, the LED's indicate the stage the node is in and its status.
When a module is in configuration mode (dipswitch value equal to ·0·), the LED's indicate
the speed selected at the module. See
LED's STOP, RUN, TX overflow and RX overflow.
The top four LED's of the module (STOP, RUN, TX overflow and RX overflow) indicate the
status of the node and of the communication through the CAN bus.
Node status.
Meaning.
Initializing stage
After starting up or after a reset, the module goes into the initializing stage
to run an autotest. During the initializing stage, the I/O LED blinks orange
until it changes to red.
• If the module is properly initialized, it changes to the pre-operative
stage, the I/O LED changes to green and the RUN LED blinks.
• If the module detects any problem in the initializing stage, it changes
to the stop stage, the I/O LED blinks red and the STOP LED turns
on. The blinking rate of the I/O LED indicates the detected error.
Pre-operative stage.
In this stage, the module configures the bus.
During the pre-operative stage, the I/O LED turns green and the RUN
LED blinks.
Operative stage.
In this stage, the module is ready to work.
In the operative stage, the I/O and RUN LED's turn green.
Stop stage.
This stage indicates an error at the node.
The STOP LED turns on in the stop stage.
STOP
RUN
Meaning.
OFF
OFF
Module turned off or in initializing stage.
OFF
Blinking
slow
Module in pre-operative stage.
OFF
ON
Module in operative stage.
ON
OFF
Module in stop stage. Node configuration error or bus error.
OFF
Blinking
fast
Module in pre-operative stage. Module error.
Blinking
fast
Blinking
fast
Module in pre-operative stage. Module error.
Blinking
fast
OFF
Module in pre-operative stage. Module error.
TX overflow
RX overflow
Meaning.
OFF
OFF
Module turned off or in initializing stage.
- - -
ON
Data reception error.
ON
- - -
Data sending error.
Blinking
fast
Blinking
fast
Too many errors at the node.
Содержание 8025 M CNC
Страница 1: ...Ref 1906 8060 8065 CNC Remote modules...
Страница 8: ...BLANK PAGE 8...
Страница 14: ...BLANK PAGE 14...
Страница 16: ...BLANK PAGE 16...
Страница 18: ...BLANK PAGE 18...
Страница 20: ...BLANK PAGE 20...
Страница 24: ...BLANK PAGE 24...
Страница 26: ...BLANK PAGE 26...
Страница 28: ...BLANK PAGE 28...
Страница 30: ...Remote modules CNC 8060 CNC 8065 1 PREVIOUS INFORMATION 30 REF 1906...
Страница 32: ...Remote modules CNC 8060 CNC 8065 2 HARDWARE STRUCTURE 32 REF 1906...
Страница 164: ...Remote modules CNC 8060 CNC 8065 7 RCS S 4F4AO SERCOS II PROTOCOL Software installation update 164 REF 1906...
Страница 177: ...Remote modules CNC 8060 CNC 8065 177 User notes REF 1906...
Страница 178: ...Remote modules CNC 8060 CNC 8065 178 User notes REF 1906...
Страница 179: ...Remote modules CNC 8060 CNC 8065 179 User notes REF 1906...