E145 ABSIND: Synchronism error at E21A feedback.
E245 ABSIND: Synchronism error at E21B feedback.
E345 ABSIND: Synchronism error at E21C feedback.
E445 ABSIND: Synchronism error at E21D feedback.
Synchronism lost between the Sercos counter and the ABSIND module which may have caused a wrong
position reading. The error is likely due to a malfunction of the ABSIND module or a connection problem
between the ABSIND module and the Sercos counter associated with that feedback. If the problem
persists, contact Fagor Automation.
E146 ABSIND: Error reading information at E21A feedback.
E246 ABSIND: Error reading information at E21B feedback.
E346 ABSIND: Error reading information at E21C feedback.
E446 ABSIND: Error reading information at E21D feedback.
It could not read the ABSIND module identification info during system startup. The error is likely due
to a malfunction of the ABSIND module or a connection problem between the ABSIND module and the
Sercos counter associated with that feedback.
If the problem persists, contact Fagor Automation.
E0147 Digital feedback. Error reading the encoder parameters. E21A feedback.
E0247 Digital feedback. Error reading the encoder parameters. E21B feedback.
E0347 Digital feedback. Error reading the encoder parameters. E21C feedback.
E0447 Digital feedback. Error reading the encoder parameters. E21D feedback.
Error during the initialization phase of the EnDat or FeeDat feedback device, during the feedback
parameter reading. The error may be due to a malfunction of the encoder or a connection problem. If
the problem persists, contact Fagor Automation.
E0148 Digital feedback. Error initializing feedback E21A.
E0248 Digital feedback. Error initializing feedback E21B.
E0348 Digital feedback. Error initializing feedback E21C.
E0448 Digital feedback. Error initializing feedback E21D.
Error in the initialization phase of the EnDat or FeeDat feedback device during the synchronous reading
of the absolute coordinate of the feedback device. The error may be due to a malfunction of the encoder
or a connection problem. If the problem persists, contact Fagor Automation.
E183 INDUCTOSYN: INC signal too low at E21A feedback.
E283 INDUCTOSYN: INC signal too low at E21B feedback.
E383 INDUCTOSYN: INC signal too low at E21C feedback.
E483 INDUCTOSYN: INC signal too low at E21D feedback.
Incremental signal level of the inductosyn/resolver feedback device too low. Check the gain and phase
values of the ABSIND module with the adjustment software. Check the cable and the connection
between the ABSIND module and the inductosyn/resolver feedback device. If the error persists and
cannot be changed with the previous actions, try replacing the ABSIND module and/or the cable
associated with that feedback. If the error persists, contact Fagor Automation.
E184 INDUCTOSYN: INC signal too high at E21A feedback.
E284 INDUCTOSYN: INC signal too high at E21B feedback.
E384 INDUCTOSYN: INC signal too high at E21C feedback.
E484 INDUCTOSYN: INC signal too high at E21D feedback.
Incremental signal level of the inductosyn/resolver feedback device too high. Check the gain and phase
values of the ABSIND module with the adjustment software. Check the cable and the connection
between the ABSIND module and the inductosyn/resolver feedback device. If the error persists and
cannot be changed with the previous actions, try replacing the ABSIND module and/or the cable
associated with that feedback. If the error persists, contact Fagor Automation.
E185 INDUCTOSYN: GRAY signal missing at E21A feedback.
E285 INDUCTOSYN: GRAY signal missing at E21B feedback.
E385 INDUCTOSYN: GRAY signal missing at E21C feedback.
E485 INDUCTOSYN: GRAY signal missing at E21D feedback.
GRAY signal level of the inductosyn/resolver feedback device missing. Check the gain and phase values
of the ABSIND module with the adjustment software. Check the cable and the connection between the
ABSIND module and the inductosyn/resolver feedback device. If the error persists and cannot be
changed with the previous actions, try replacing the ABSIND module and/or the cable associated with
that feedback. If the error persists, contact Fagor Automation.
Содержание 8025 M CNC
Страница 1: ...Ref 1906 8060 8065 CNC Remote modules...
Страница 8: ...BLANK PAGE 8...
Страница 14: ...BLANK PAGE 14...
Страница 16: ...BLANK PAGE 16...
Страница 18: ...BLANK PAGE 18...
Страница 20: ...BLANK PAGE 20...
Страница 24: ...BLANK PAGE 24...
Страница 26: ...BLANK PAGE 26...
Страница 28: ...BLANK PAGE 28...
Страница 30: ...Remote modules CNC 8060 CNC 8065 1 PREVIOUS INFORMATION 30 REF 1906...
Страница 32: ...Remote modules CNC 8060 CNC 8065 2 HARDWARE STRUCTURE 32 REF 1906...
Страница 164: ...Remote modules CNC 8060 CNC 8065 7 RCS S 4F4AO SERCOS II PROTOCOL Software installation update 164 REF 1906...
Страница 177: ...Remote modules CNC 8060 CNC 8065 177 User notes REF 1906...
Страница 178: ...Remote modules CNC 8060 CNC 8065 178 User notes REF 1906...
Страница 179: ...Remote modules CNC 8060 CNC 8065 179 User notes REF 1906...