manualshive.com logo in svg
background image

2012/19/UE 

Directive

  Disposal of electric and

    electronic waste

DISPOSE PROPERLY OF MATERIALS

HARMFUL TO THE ENVIRONMENT

GB

Via Mantova, 177/A - 37053 Cerea (VR) Italy 

Ph. +39 0442 330422 

Fax +39 0442 331054

[email protected] - www.fadini.net

16

Pic. 9

MANUAL RELEASE OPERATIONS

3

2

1

GUIDANCE FOR PROPER USE

 (for the end user)

• Transit across the gate is allowed only if motor is stopped; stand at safe distance during opening and/or closing cycles of the gate.

• Do not touch any components of the system while the operator is working.

• Do not allow children and/or people to stand in the proximity of a working operator.

• Keep all the accessories able to turn on the operator (transmitters, proximity readers, key-switches, etc.) out of the reach of the children.

• Do not run the system in case of anomalies.

DISPOSAL OF MATERIAL

: dispose properly of the packaging materials such as cardboard, nylon, polystyrene etc. through specializing 

companies (after veri cation of the regulations in force at the place of installation in the  eld of waste disposal). Disposal of electrical and

electronic  materials:  to  remove  and  dispose  through  specializing  companies,  as  per  Directive  2012/19/UE.  Disposal  of  substances 

hazardous for the environment is prohibited.

WARNINGS

For  optimum  performance  of  system  over  time  according  to  safety  regulations,  it  is  necessary  to  perform  proper  maintenance  and 

monitoring of the entire installation: the automation, the electronic equipment and the cables connected to these. The entire installation 

must be carried out by quali ed technical personnel. Operator: maintenance inspection at least every 6 months, while for the electronic 

equipment  and  safety  systems  an  inspection  at  least  once  every  month  is  required. The  manufacturer,  Meccanica  Fadini  snc,  is  not 

responsible for non-observance of good installation practice and incorrect maintenance of the installation.

Advice for the end user

:

• clear the site of materials that may have deposited in the equipment and hinder its correct functioning (such as rests of insects, foliage, 

stones, etc.); before carrying out this operation, switch off voltage supply;

• clean regularly the equipment by using a damp cloth. Do not use  ammable substances such as alcohol, solvents or benzene: these 

substances may cause explosions and/or damage the system.

MAINTENANCE

KIT with oil-hydraulic operators for swinging gates 

up to 2,5 m per gate leaf

NUPI 66

20211118

Содержание NUPI 66

Страница 1: ...241 EN 12453 EN 12445 NUPI 66 KIT pistone oleodinamico per cancelli a battente con ante no 2 5 m I pag 1 8 I Libretto di istruzioni pag 9 16 GB Instructions manual pages 17 24 F Notice d instructions...

Страница 2: ...Nel caso in cui il cancello da automatizzare fosse dotato di un ingresso pedonale opportuno predisporre l impianto in maniera tale da interdire il funzionamento del motore quando l ingresso pedonale u...

Страница 3: ...ghezza anta da applicare al pilastro e sull anta e come particolarit non presenta la necessit di nessuna regolazione di registri di massima e minima spinta poich tali funzioni sono eseguite elettronic...

Страница 4: ...Elettroserratura per ante oltre i 2 metri di lunghezza non fornita nel kit 12 Trasmettitore fornito nel kit 230 V 50 Hz 10 1 2 3 4 5 6 6 8 8 5 9 9 4 7 10 12 11 Fig 2 Fig 3 Vedere operazioni sblocco m...

Страница 5: ...te di installazione siano corrette per un apertura di 90 QUOTE DI INSTALLAZIONE PER APERTURA VERSO L INTERNO Piastra metallica di rinforzo optional Per installazioni pesanti si consiglia di adeguare i...

Страница 6: ...ICO Potenza resa 0 18 kW 0 25 CV Tensione di alimentazione 230 Vac Frequenza 50 Hz Corrente assorbita 1 2 A Potenza assorbita 250 W Condensatore 12 5 F Velocit rotazione motore 1 350 rpm Servizio inte...

Страница 7: ...tallazione Quantit dei modelli installati Manutentore Data ATTENZIONE questo documento deve contenere gli interventi ordinari e straordinari di installazione manutenzione riparazione e le modi che di...

Страница 8: ...i a ditte specializzate nel recupero dei ri uti come indicato nella direttiva 2012 19 UE Vietato gettare nei ri uti materiali nocivi per l ambiente AVVERTENZE Per una resa ottimale dell impianto nel t...

Страница 9: ...EN 13241 EN 12453 EN 12445 NUPI 66 KIT with oil hydraulic operators for swinging gates up to 2 5 m per gate leaf 9 16 GB Instructions manual pages the gate opener 9...

Страница 10: ...to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on the gate warning about the presence of an a...

Страница 11: ...te leaves not wider than 2 meters and designed to be mounted on to the gate and gate post Its peculiar feature is that thrust power setting into low and high is not by valves being this function elect...

Страница 12: ...ck for gate leaves wider than 2 meters not in the kit 12 Transmitter included in the kit 2 3 4 5 6 6 8 8 5 9 9 4 7 10 12 11 Pic 2 Pic 3 The electric cable is to dangle without sharp bending all along...

Страница 13: ...d a proper 90 opening can so be achieved FIXING GEOMETRY WITH DISTANCES FOR THE GATES TO OPEN INWARDS Metal patch plate to strengthen the xing point optional With heavy installations it is recommended...

Страница 14: ...08L Piston stroke 275 mm Piston diameter 45 mm Piston shaft diameter 16 mm Working temperature 20 C 80 C A Operator weight complete 8 kg Single gate max weight 400 kg Single gate max width 2 5 m Prote...

Страница 15: ...ions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installatio...

Страница 16: ...se through specializing companies as per Directive 2012 19 UE Disposal of substances hazardous for the environment is prohibited WARNINGS For optimum performance of system over time according to safet...

Страница 17: ...EN 13241 EN 12453 EN 12445 NUPI 66 KIT v rin hydraulique pour portails battant avec vantaux jusqu 2 5 m 17 24 F Notice d instructions pages l ouvre portail 17...

Страница 18: ...atiser aurait dou d une entr e pi tonne il serait bon d accomplir l installation de fa on que le moteur ne fonctionne pas lorsque l entr e pi ton est utilis Fournir des indications concernant la posit...

Страница 19: ...passent pas les 2 m tres de largeur par vantail Il doit tre appliqu sur le pilier et sur le vantail et il n a pas besoin du r glage des registres de pouss e max et min puisque ces fonctions sont suivi...

Страница 20: ...x jusqu 2 5 m PREMIERES MANOEUVRES POUR SORTIR LA TIGE La tige peut tre d plac e manuellement voir Fig 3 ou lectriquement par alimentation lectrique D placez la tige mi chemin NUPI 66 230 V 50 Hz 10 1...

Страница 21: ...ont correctes pour une ouverture de 90 DISTANCES D INSTALLATIONS POUR L OUVERTURE VERS L INTERIEUR Plaque m tallique renforc e en option Pour les installations lourdes il est conseill d ajuster le ren...

Страница 22: ...ge 275 mm Diam tre v rin 45 mm Diam tre tige 16 mm Temp rature d exercice 20 C 80 C A Poids complet Nupi 66 8 kg Poids max vantail 400 kg Largeur max vantail 2 5 m Degr de protection complet IP 67 Enc...

Страница 23: ...imensions vantail Poids vantail Date de fabrication Quantit mod les install s Mainteneur Date ATTENTION Ce document contient le registre des installations entretiens r parations et am liorations ordin...

Страница 24: ...d chets comme indiqu dans la directive 2012 19 UE Il est interdit de jeter dans les d chets des mat riaux nocifs pour l environnement AVERTISSEMENTS Pour un fonctionnement optimal du syst me dans le t...