background image

Aproli 280 /700 

Robusto

400

English

6

INSTALLATION DISTANCES

Aproli 280/700 Robusto comes with an arm whose gate fixing end can be adjusted into three lengths (460, 520 and 580 mm):

FIXING THE BRACKET TO THE GATE POST 

The support bracket is to be fixed by expanding bolts suitably to the post nature and using four of the eight holes in it.

50

Pic. 5

90° 

Fixing distances (mm) for 

90° 

opening angle

Pic. 6

APROLI 280/700

Robusto

[B]:

 The distances indicated in the table have been calculated on a gate having a thickness of 50 mm and a gate hinge 

positioned at 50 mm from gate post. The above considerations can be applied even to gates having a different size, 
leaving to the experience and technical skill of the installer the task of assessing the most suitable fixing geometry. 

M8 fixing bolts to suit 

gate post or

wall nature 

250 

150 

212 

120 

355 

External oil-hydraulic operator with articulated arm

for swinging gates mounted on large pillars

C = 460 - 520 - 580 mm

400 mm 

70 150 

 

460 

75 650

70 200 

460 

70 650

70  250 520 120 650

70 300 

520 

85 650

70  350 580 150 650

70  400 580 100 650

70 450 

580 

0  600

[B]

 

  B  

 C 

  L 

istr_aproli280-700robusto_GB.ai   6   28/04/2022   14:43:05

Содержание APROLI 280 Robusto

Страница 1: ...EN 13241 EN 12453 EN 12445 APROLI 280 700 Robusto External oil hydraulic operator with articulated arm for swinging gates mounted on large pillars 1 12 GB Instructions manual pages the gate opener...

Страница 2: ...pped with a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marki...

Страница 3: ...y made of galvanized steel and aluminium and fixed by screws The pivoting shaft is made of hardened steel to ensure long lasting reliability over the time The driving arm right or left handed version...

Страница 4: ...r 5 Photocell receiver 6 Junction pit 7 Photocell transmitter on post mount 8 Ground gate stop in open position A 9 Photocell receiver on post mount 10 Gate electric lock recommended beyond 2 m width...

Страница 5: ...penings at the back side towards the gate post and two in the bottom in this way it can meet any application requirements Pic 4 Pic 3 Pic 4 English 5 Aproli 280 700 Robusto by factory default is a han...

Страница 6: ...in the table have been calculated on a gate having a thickness of 50 mm and a gate hinge positioned at 50 mm from gate post The above considerations can be applied even to gates having a different si...

Страница 7: ...oli 280 700 Robusto onto the support bracket the right and left versions are marked Dx and Sx on the aluminium casting as indicated in Pic 7 Pic 7 Gate view from inside Dx Sx Sx Dx Aproli 280 700 Robu...

Страница 8: ...djusting screws on the motor pump casting Pic 10 FITTING THE FRONT COVER BACK Once setting is completed first put the operator cover back and secure it by the screws then close the flap by the key Pic...

Страница 9: ...25 CV Supply voltage 230 Vac Frequency 50 Hz Absorbed power 250 W Absorbed current 1 2 A Motor rotation speed 1 350 rpm Capacitor 12 5 F Intermittent service S3 APPLICATIONS Max gate weight per leaf 4...

Страница 10: ...English APROLI 280 700 Robusto 10 External oil hydraulic operator with articulated arm for swinging gates mounted on large pillars...

Страница 11: ...perator model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services i...

Страница 12: ...l of substances hazardous for the environment is prohibited WARNINGS For optimum performance of system over time according to safety regulations it is necessary to perform proper maintenance and monit...