background image

2

External oil-hydraulic operator with articulated arm

for swinging gates mounted on large pillars

English

APROLI 280/700

Robusto

GENERAL WARNINGS FOR PEOPLE SAFETY

THANK YOU

Thank you for purchasing a Fadini product. 
Please read these instructions carefully before using this 
appliance. The instructions contain important information 
which will help you get the best out of the appliance and 
ensure safe and proper installation, use and maintenance. 
Keep this manual in a convenient place so that you can always 
refer to it for the safe and proper use of the appliance.

INTRODUCTION 

This operator is designed for a specific scope of applications as 
indicated in this manual, including safety, control and signaling 
accessories as minimum required with Fadini equipment. 

 Any 

applications not explicitly included in this manual may cause 
operation problems or damages to properties and people. 

 

Meccanica Fadini snc is not liable for damages caused by the 
incorrect use of the equipment, or for applications not included 
in this manual or for malfunctioning resulting from the use of 
materials or accessories not recommended by the 
manufacturer. 

 The manufacturer reserves the right to make 

changes to its products without prior notice. 

 All that is not 

explicitly indicated in this manual is to be considered not 
allowed.

BEFORE INSTALLATION

Before commencing operator installation assess the suitability 
of the access, its general condition and the structure. 

 Make 

sure that there is no risk of impact, crushing, shearing, 
conveying, cutting, entangling and lifting situations, which 
may prejudice people safety. 

 Do not install near any source of 

heat and avoid contacts with flammable substances. 

 Keep all 

the accessories able to turn on the operator (transmitters, 
proximity readers, key-switches, etc) out of the reach of the 
children. 

 Transit through the access only with stationary 

operator. 

 Do not allow children and/or people to stand in the 

proximity of a working operator. 

 To ensure safety in the 

whole movement area of a gate it is advisable to install 
photocells, sensitive edges, magnetic loops and detectors. 

 

Use yellow-black strips or proper signals to identify dangerous 
spots. 

 Before cleaning and maintenance operations, 

disconnect the appliance from the mains by switching off the 
master switch. 

 If removing the actuator, do not cut the 

electric wires, but disconnect them from the terminal box by
loosening the screws inside the junction box.

INSTALLATION

All installation operations must be performed by a qualified 
technician, in observance of the Machinery Directive 
2006/42/CE and safety regulations EN 12453 - EN 12445. 

Verify the presence of a thermal-magnetic circuit breaker
0,03 A - 230 V - 50 Hz upstream the installation. 

 Use 

appropriate objects to test the correct functionality of the 
safety accessories, such as photocells, sensitive edges, etc. 

 

Carry out a risk analysis by means of appropriate instruments 
measuring the crushing and impact force of the main opening 
and closing edge in compliance with EN 12445. 

 Identify the 

appropriate solution necessary to eliminate and reduce such
risks. 

 In case where the gate to automate is equipped with a 

pedestrian entrance, it is appropriate to prepare the system in 
such a way to prohibit the operation of the engine when the 
pedestrian entrance is used. 

 Apply safety nameplates with 

CE marking on the gate warning about the presence of an 
automated installation. 

 The installer must inform and 

instruct the end user about the proper use of the system by 
releasing him a technical dossier, including: layout and 
components of the installation, risk analysis, verification of 
safety accessories, verification of impact forces and reporting 
of residual risks.

INFORMATION FOR END-USERS

The end-user is required to read carefully and to receive 
information concerning only the operation of the installation 
so that he becomes himself responsible for the correct use of it. 

 The end-user shall establish a written maintenance contract 

with the installer/maintenance technician (on -call). 

 Any 

maintenance operation must be done by qualified technicians. 

 Keep these instructions carefully.

WARNINGS FOR THE CORRECT OPERATION OF THE 
INSTALLATION

 

For optimum performance of system over time according to 
safety regulations, it is necessary to perform proper 
maintenance and monitoring of the entire installation: the 
automation, the electronic equipment and the cables 
connected to these. 

 The entire installation must be carried 

out by qualified technical personnel, filling in the Maintenance 
Manual indicated in the Safety Regulation Book (to be 
requested or downloaded from the site 
www.fadini.net/supporto/downloads). 

 Operator: maintenance inspection at least every 6 months, 

while for the electronic equipment and safety systems an 
inspection at least once every month is required. 

 The 

manufacturer, Meccanica Fadini snc, is not responsible for 
non-observance of good installation practice and incorrect 
maintenance of the installation.

DISPOSAL OF MATERIALS

Dispose properly of the packaging materials such as 
cardboard, nylon, polystyrene etc. through specializing 
companies (after verification of the regulations in force at the 
place of installation in the field of waste disposal). Disposal of 
electrical and electronic materials: to remove and dispose 
through specializing companies, as per Directive 2012/19/UE. 
Disposal of substances hazardous for the environment is
prohibited.

Meccanica Fadini s.n.c.

Director in charge

CE DECLARATION OF CONFORMITY of the manufacturer:

Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under own responsibility that:

APROLI 280/700 Robusto

 complies with the 2006/42/CE Machinery Directive, and also that it is sold to be installed in an 

“automatic system”, along with original accessories and components as indicated by the manufacturing company. An 
automatic gate operator is, by law, a “machinery” and therefore the installer must fit the equipment with all of the 
applicable safety norms. The installer is also required to issue the installer’s Declaration of Conformity. The manufacturer is 
not liable for possible incorrect use of the product. The product complies with the following specific norms: analysis of the 
risks and subsequent action to cure them as per EN 12445 and EN 12453, Low Voltage Directive 2014/35/UE, 
Electromagnetic Compatibility 2014/30/UE. In order to certify the product, the manufacturer declares under own 
responsibility the compliance with the EN 13241-1 PRODUCT NORMS.

istr_aproli280-700robusto_GB.ai   2   28/04/2022   14:43:04

Содержание APROLI 280 Robusto

Страница 1: ...EN 13241 EN 12453 EN 12445 APROLI 280 700 Robusto External oil hydraulic operator with articulated arm for swinging gates mounted on large pillars 1 12 GB Instructions manual pages the gate opener...

Страница 2: ...pped with a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marki...

Страница 3: ...y made of galvanized steel and aluminium and fixed by screws The pivoting shaft is made of hardened steel to ensure long lasting reliability over the time The driving arm right or left handed version...

Страница 4: ...r 5 Photocell receiver 6 Junction pit 7 Photocell transmitter on post mount 8 Ground gate stop in open position A 9 Photocell receiver on post mount 10 Gate electric lock recommended beyond 2 m width...

Страница 5: ...penings at the back side towards the gate post and two in the bottom in this way it can meet any application requirements Pic 4 Pic 3 Pic 4 English 5 Aproli 280 700 Robusto by factory default is a han...

Страница 6: ...in the table have been calculated on a gate having a thickness of 50 mm and a gate hinge positioned at 50 mm from gate post The above considerations can be applied even to gates having a different si...

Страница 7: ...oli 280 700 Robusto onto the support bracket the right and left versions are marked Dx and Sx on the aluminium casting as indicated in Pic 7 Pic 7 Gate view from inside Dx Sx Sx Dx Aproli 280 700 Robu...

Страница 8: ...djusting screws on the motor pump casting Pic 10 FITTING THE FRONT COVER BACK Once setting is completed first put the operator cover back and secure it by the screws then close the flap by the key Pic...

Страница 9: ...25 CV Supply voltage 230 Vac Frequency 50 Hz Absorbed power 250 W Absorbed current 1 2 A Motor rotation speed 1 350 rpm Capacitor 12 5 F Intermittent service S3 APPLICATIONS Max gate weight per leaf 4...

Страница 10: ...English APROLI 280 700 Robusto 10 External oil hydraulic operator with articulated arm for swinging gates mounted on large pillars...

Страница 11: ...perator model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services i...

Страница 12: ...l of substances hazardous for the environment is prohibited WARNINGS For optimum performance of system over time according to safety regulations it is necessary to perform proper maintenance and monit...